Chapter 8 LUN Recognition
>
8.2 Displaying the Recognized Logical Units
8.2.2

For SUSE Linux Enterprise Server

Checking for LUNs in the boot message
Open the /var/log/boot.msg file to confirm that Linux has recognized the ETERNUS Disk
storage systems' LUNs.
The following shows an example (Messages can be scrolled (back and forth) using the arrow
keys).
<5> Vendor: FUJITSU Model: E2000 Rev: 0000
<5> Type: Direct-Access ANSI SCSI revision: 05
<5> Vendor: FUJITSU Model: E2000 Rev: 0000
<5> Type: Direct-Access ANSI SCSI revision: 05
<5>SCSI device sdb: 4096000 512-byte hdwr sectors (2147 MB)
<7> sdb: unknown partition table
<5>SCSI device sdc: 4096000 512-byte hdwr sectors (2147 MB)
<7> sdc: unknown partition table
Checking for LUNs with the "cat" command
Use the "cat" command to display the "/proc/scsi/scsi" file, which contains a list of recognized
SCSI devices.
The following shows an example of this.
At this point the Multipath Driver has not been set up yet, so two SCSI devices are shown for
each connected LUN (i.e. if there are 3 LUNs, 6 SCSI devices are shown).
P3AM-4212-02ENZ0
ETERNUS2000 Disk storage systems Server Connection Guide (SAS) for Linux
:
:
:
# cat /proc/scsi/scsi
Attached devices:
Host: scsi0 Channel: 02 Id: 00 Lun: 00
Vendor: LSI
Model: MegaRAID SAS RMB Rev: 1.02
Type:
Direct-Access
Host: scsi1 Channel: 00 Id: 01 Lun: 00
Vendor: FUJITSU
Model: E2000
Type:
Direct-Access
Host: scsi1 Channel: 00 Id: 01 Lun: 01
Vendor: FUJITSU
Model: E2000
Type:
Direct-Access
Host: scsi1 Channel: 00 Id: 01 Lun: 02
Vendor: FUJITSU
Model: E2000
Type:
Direct-Access
Host: scsi1 Channel: 00 Id: 01 Lun: 03
Vendor: FUJITSU
Model: E2000
Type:
Direct-Access
Host: scsi1 Channel: 00 Id: 01 Lun: 04
Vendor: FUJITSU
Model: E2000
Type:
Direct-Access
ANSI SCSI revision: 05
Rev: 0000
ANSI SCSI revision: 05
Rev: 0000
ANSI SCSI revision: 05
Rev: 0000
ANSI SCSI revision: 05
Rev: 0000
ANSI SCSI revision: 05
Rev: 0000
ANSI SCSI revision: 05