Linear RA-2400 Reference Manual For Programming page 24

Remote access pers-3600 personal emergency reporting system
Hide thumbs Also See for RA-2400:
Table of Contents

Advertisement

4.6
SENSORS (CONTINUED)
DELAYED ALARM SETTING
Click on the sensor number in the menu tree to view it.
View or edit the DELAYED ALARM SETTING.The delayed alarm settings are:
DISABLED: An alarm transmission received from the selected sensor will not be delayed.
15 MINUTE DELAY: An alarm transmission received from the selected sensor will be delayed for 15 minutes.
30 MINUTE DELAY: An alarm transmission received from the selected sensor will be delayed for 30 minutes.
NOTE: If a transmitter restore is received prior to the timeout period, then the alarm
will be automatically cancelled and the unit will return to normal standby operation.
The Delayed Alarm Setting is ignored for Fire and Activity Reset sensors.
SENSOR OPTIONS
View or edit the SENSOR OPTIONS. These options are automatically set when
the sensor is programmed into the Console. The sensor options are:
AUTO RESTORE: This box should be checked for all model sensors except the Model DXS-31.
SUPERVISED: This box should be checked for all sensors that send periodic status reports. DXT sensors
do not send periodic status reports. REMOVE THE CHECK FROM THIS BOX IF A MODEL DXT SENSOR
HAS BEEN PROGRAMMED INTO THIS SENSOR LOCATION or if you don't want supervision for a DXS
sensor. This will keep the Console STATUS indicator from lighting due to missing status reports.
NOTE: The sensor can still report a low battery condition (see Section 4.9)
this will cause the Console's STATUS indicator to fl ash.
SILENT ALARM: This box should be checked for all sensors that need to be silent locally. Fire or Activity
Reset sensors will not be silent.
TWO-WAY VOICE ACTIVATION: This box should be checked for all sensors that require two-way voice
activation. Checking this box will not enable Two-way audio if NONE is selected in the CONSOLE AUDIO
screen (see Section 4.5).
SENSOR STATUS
View the SENSOR STATUS to see the condition of the sensor
selected. The sensor status conditions are:
LOW BATTERY: The sensor has sent a low battery signal to the Console. Replace the sensor's battery.
TROUBLE: The Console has not received a status report from this sensor in 24 hours. Sensor may have
been out of range of the Console's receiver, or the sensor may be non-functional.
NOTE: After any changes are made to the sensor type or sensor
options, test the sensor to verify proper operation.
22

Advertisement

Table of Contents
loading

Table of Contents