Cleaning Air Cleaner Primary Element - Kubota M100GX Operator's Manual

Hide thumbs Also See for M100GX:
Table of Contents

Advertisement

(1) Grease fitting (Top link)
(2) Grease fitting (Lifting rod) [LH]
(3) Grease fitting (Lifting rod) [RH]
(1) Grease fitting (Hydraulic lift cylinders pin)
(1) Grease fitting (Hydraulic arm axle)
(1) Battery terminals
BCleaning Air Cleaner Primary Element
1. Remove the air cleaner cover and primary element.
2. Clean the primary element:
(1) When dry dust adheres to the element, blow
compressed air from the inside, turning the
element. Pressure of compressed air must be
under 205 kPa (2.1 kgf/cm , 30 psi).
(2) When carbon or oil adheres to the element, soak
the element in detergent for 15 minutes then wash
it several times in water, rinse with clean water
and dry it naturally. After element is fully dried,
inspect inside of the element with a light and
check if it is damaged or not.
3. Replace air cleaner primary element:
Once yearly or after every sixth cleaning, whichever
comes first.
A Check to see if the evacuator valve is blocked with
dust.
(1) Secondary (safety) element
(2) Primary element
(3) Evacuator valve
(4) Cover
PERIODIC SERVICE
(A) "ARROW"
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M110gxM126gxM135gx

Table of Contents