1.18
D S A N D H L P O W E R SAVE OPTIONS
The drive is set upwith the HL option in. This stepper power from head load line option supplies power
to the stepper motor when the head load line goes low (true), which results in lower stand-by current
consumption. As shipped from the factory, HL is installed but will remove power from the stepper
motor when the d r ive is deselected. There should be a 2 0
command is given in order to allow the step motor electronics to settle.
The stepper power from drive select, DS option, allows the user to re move D. C. power from the
stepper motor using drive select, which results in lower stand-by current consumption. This option is
implemented by installing DS, and cutting HL.
1.19
US ER S E L E C TABLE OPTIONS
The description of user selectable options should be used in conjunction with the following list of
options that are available for model numbers TM848-1 and TM848-2 (see Table 1-5).
OPTION
Drive Select
Side Select Options using Drive Select
In Use, Drive Select
In Use, Head Load
Ready Alternate Output Pad
Radial Ready
Ready, Modified
Radial Index
Index, Alternate Output Pad
In Use, Alternate Output Pad
Diskette Lever Lock Latch Option
Disk Change
Two-Sided Diskette Installed
Stepper Power from Drive Select
Stepper Power from Head Load Line
Head Load Alternate Output Pad
Radial Head Load Signal
Radial Head Load Signal
Radial Head Load Signal
Inhibit Write When Write Protected
Allow Write When Write Protected
Head Side Select Options
Spindle Motor Control Options
Motor Control Select
m i l lisecond wait after a Drive Select
TABLE 1-5
OPTIONS
TRACE
Shunt/Pin
DESIG NATOR
Locations
DS1-DS4
1 B-4B
U3, 1-16
Z
Y R
U3, 7-10
RR
RM
Rl
U3, 6-11
D
DL
DC
2S
DS
HL
U3, 2-15
U3, 3-14
C A B X
U3, 4-13
U3, 5-12
WP
NP
S1-S3
M1-M4
MC1-MC4
1-17
A S S H I P P E D
Not
Installed
Installed
DS1
X X
X X X X
X
S2
M1, M3
M2, M4
MC1