1.7

Installing/Mounting

1.7.1

Permitted mounting positions

Mounting positions
Only vertical mounting at angles up to +45° and -45° are permitted for the device.
Rear
0° - 50° C
0° to 45°C
For RAL mounting only (RAL = Restricted Access Location)
1)
(installation of device in operating facilities with restricted access - for example, a locked
control cabinet)
Mechanical environmental conditions
● Vibration
SIMATIC HMI IPC477C / HMI IPC477C PRO
Compact Operating Instructions, 10/2010, A5E02368072-02
Temperature at the device
Front
Max. 40°C
1)
0° to 45°C
– Operation, tested in accordance with DIN IEC 60068-2-6
10 to 58 Hz: 0.075 mm 58 to 200 Hz: 9.8 m/s²
– Storage/transport, tested according to IEC 60068-2-27, IEC 60068-2-29
50 m/s², 30 ms
250 m/s², 6 ms