Yamaha XV19SX(C) Service Manual page 468

Table of Contents

Advertisement

3. Remove:
• Coupler tray "1"
1
4. Disconnect:
• Battery leads
(from the battery terminals)
ECA13640
CAUTION:
First, disconnect the negative battery lead
"1", and then positive battery lead "2".
1
5. Remove:
• Battery
6. Check:
• Battery charge
M
MMM
M MMM
M
M MMM
M
M MMM
M
a. Connect a pocket tester to the battery termi-
nals.
• Positive tester probe →
positive battery terminal
• Negative tester probe →
negative battery terminal
1
2
M MMM
M
M MMM
M
MMM
7-77
ELECTRICAL COMPONENTS
NOTE:
• The charge state of an MF battery can be
checked by measuring its open-circuit voltage
(i.e., the voltage when the positive battery ter-
minal is disconnected).
• No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown in
the charts and the following example.
Example
Open-circuit voltage = 12.0 V
Charging time = 6.5 hours
Charge of the battery = 20–30%
A. Open-circuit voltage (V)
B. Charging time (hours)
C. Relationship between the open-circuit voltage
and the charging time at 20 °C (68 °F)
D. These values vary with the temperature, the
condition of the battery plates, and the
electrolyte level.
A. Open-circuit voltage (V)
B. Charging condition of the battery (%)
C. Ambient temperature 20 °C (68 °F)
L
LLL
L LLL
L
L LLL
L
L LLL
L
7. Charge:
• Battery
(refer to the appropriate charging method il-
lustration)
L LLL
L
L LLL
L
LLL