Polaris 2007 Sportsman 500 EF Service Manual page 326

Atv polaris 2007 sportsman 450 / 500 efi / 500 x2 efi
Table of Contents

Advertisement

CHARACTERISTIC PARAMETER
Operating Temperature
Storage Temperature
CHARACTERISTIC MIN TYP MAX UNIT
Battery Voltage
Batt. Quiescent Current
Regulator Voltage
Regulator Output
Over-Voltage Threshold
Minimum Battery Voltage
Alternator Coil 1 Resistance
Output Current
Limit
Time Delay
Voltage
Current Output
Output Limit
Overload Delay
Output Current
Rep. Short-circuit Limit
Output Current
Rep. Short-circuit Limit
Output Current
Rep. Short-circuit Limit
Fan Motor Current
Over-current Limit
Fan Load Open Delay
Fan Stall On Time
Fan Stall Off Time
UNIT
°C
-40 to +55
°C
-50 to +85
10.5
14.4
16
Vdc
1.5
2
mA
REGULATOR
14.1
14.4
14.8
Vdc
25
32
Adc
16
Vdc
2
Vdc
15k
Ohm
BAT_PROT OUTPUT
20
Amp
30
Amp
0.6
Sec
6.2
Vdc
ECM RELAY OUTPUT
20
Amp
30
Amp
0.6
Sec
IGNITION RELAY OUTPUT
10
25
Amp
26
Amp
ACC_PWR OUTPUT
10
25
Amp
26
Amp
FUEL PUMP OUTPUT
10
25
Amp
26
Amp
FAN RELAY CONTROLLER
10
12
Amp
18
Amp
5
Sec
2
Sec
10
Sec
NOTE
Ambient temperatures at which module
should remain within specified limits
Ambient temperatures which should
have no adverse effects
on module operation
NOTE
PDM functions will operate over this range
Min. draw from battery with key off
Max. total DC amperage available from regulator
Battery voltage that will cause
the regulator to temporarily turn off
Min. voltage required on RUN for
regulator to begin operation
Resistance between alternator signal and ground
Only on this designated alternator signal
Nominal Continuous output current
Current level that will cause turn off after delay
Time above limit until SSCB trips
Min Battery voltage for BAT_PROT to remain on
Nominal continuous output
Current level that will cause turn off after delay
Time above limit until ECM Relay trips
Max. continuous current
Typical limit to cause repetitive thermal cycling
Max. continuous current
Typical limit to cause repetitive thermal cycling
Max. continuous current
Typical limit to cause repetitive thermal cycling
Current capability of the FAN output
Threshold to start fan stall delay timer
Time delay after detection of open fan load
Time FAN output will remain on
after current limit
exceeded
Time FAN output will remain off after current limit
exceeded. FAN_STAT on during this time
ELECTRICAL
10
10.8

Hide quick links: