3. Entering a special mode

1 Entering the process adjustment mode

[Steps]
(1) When using the remote controller:
Using the system cable, properly connect the plasma display and the media receiver, and then turn ON
the power.
After the system has started up, press the PROCESS ADJ button located on the remote controller.
(2) When using buttons on the main unit:
Using the system cable, properly connect the plasma display and the media receiver.
Turn ON the power while holding down the INPUT SELECT button and Vol UP button located the plasma
display.
[Description]
Various adjustments can be made manually.

2 Entering the inspection process mode

[Steps]
After the system has started up, press the PROCESS ADJ button located on the remote controller.
Set the parameter SIGNAL INFO to 1 on page 6 of the PROCESS ADJUSTMENT A MODE MENU.
Subsequently, make the necessary adjustments in accordance with the above menu.
3 Procedure for setting up delivery
[Steps]
After the system has started up, press the DELIVERY SETUP button located on the remote controller.
(Within the adjustment process, the channel settings remain unchanged. Once you exit the process adjustment
mode, the channel settings entered in the delivery adjustment mode become valid.)
[Description]
The user's adjustment parameters and others will be set to the default values. The channel settings will also
be initialized.
4. Exiting a special mode
(1) Process adjustment mode: Press the PROCESS ADJ button located on the remote controller or turn OFF the
power.
(2) Inspection process mode: Set the parameter SIGNAL INFO to 0 on page 6 of the PROCESS ADJ A MODE
MENU or turn OFF the power.
(3) Delivery setup: After the delivery setup has been finished, the process adjustment mode is automatically
selected. To exit the process adjustment mode, press the PROCESS ADJ button located on the remote controller
or turn OFF the power.
5. OSD menu and parameters displayed at manual adjustment
* The default values may slightly differ depending upon the program version to be rewritten.
* The settings are not initialized to the default values by merely rewriting the program. (See the paragraph for
Preparation for adjustment.)
(1) Descriptions of special buttons in process adjustment mode
Cursor UP key
Cursor DOWN key : Returns to the previous page.
Vol UP key
Vol DOWN key
Cursor LEFT key : Increases the adjusted value by 10.
Cursor RIGHT key : Decreases the adjusted value by 10.
Tuning UP key
Tuning DOWN key : Moves down the cursor.
: Proceeds to the next page.
: Increases the adjusted value by 1.
: Decreases the adjusted value by 1.
: Moves up the cursor.