Superior DRT4040DMN Installation And Operation Instruction Manual page 19

Superior drt40 series direct vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior
DRT40 Direct Vent Gas Fireplace
TM
VERTICAL VENT FIGURES/TABLES
(continued)
TABLE C
H
+H
Maximum
H Maximum
1
(meters)
feet
feet
(1.524)
5
2
(3.048)
10
4
(4.572)
15
6
(6.096)
20
8
V + V 1 + H + H 1 = 40 feet (12.2 m) Max
H = 8 feet (2.438 meters) Max.
H + H 1 = 20 feet (6.096 meters) Max.
Example: If 20 feet of (H) horizontal vent run is needed, then
4 feet minimum of (V) vertical vent will be required.
This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of
(V) vertical, you are allowed 5 feet of (H) horizontal run, up
to a maximum horizontal run of 20 feet.
NOTE: Install the U-shaped vent restrictor in any vent run with
more than 8 ft. of vertical rise. See Page 14.
Figure 32 - Rear Vent - THREE ELBOWS
TABLE D
H +
Maximum
H
1
feet
(meters)
feet
(1.524)
5
(1.524)
5
(3.048)
10
(4.572)
15
(6.096)
20
H + H
= 20 feet (6.096 m) Max.
1
V + V
+ H + H
= 40 ft. (12.192 m) Max.
1
1
Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet
minimum of (V) vertical vent will be required.
This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V) verti-
cal, you are allowed 5 feet of (H) horizontal run, up to a maximum
horizontal run of 20 feet.
An elbow is acceptable as 1 foot of vertical rise except where an
elbow is the only vertical component in the system. See Figure 38.
NOTE: Install the U-shaped vent restrictor in any vent run with more than
8 ft. of vertical rise. See Page 14.
Figure 33 - Top Vent - THREE ELBOWS
V Minimum
(meters)
(meters)
feet
(0.610)
(0.305)
1
(1.219)
(0.610)
2
(1.829)
(0.914)
3
(2.438)
(1.219)
4
V Minimum
(meters)
Elbow Only
(0.305)
1
(0.610)
2
(0.914)
3
(1.219)
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
H1
Ceiling
Firestop/Spacer
SV4.5VF*
Wall
Firestop/Spacer
SV4.5HF**
V1
V
Ceiling
Firestop/Spacer
V 1
SV4.5VF*
H 1
*When using Secure Flex, use
Ceiling Firestop/Spacer SF4.5VF.
**When using Secure Flex, use
Wall Firestop/Spacer SF4.5HF.
Installation and Operation Instructions
900357-00, 06/2015
*When using Secure Flex, use
Ceiling Firestop/Spacer SF4.5VF.
**When using Secure Flex, use
Wall Firestop/Spacer SF4.5HF.
Ceiling
Firestop/Spacer
SV4.5VF*
H
Wall
Firestop/Spacer
SV4.5HF**
H
V
19