10-2. Optional Parts, Accessories and Tools
10-2-1. Optional Installation Parts
Part code
Indoor unit name
Y
RAS-B10SKVP-E, B13SKVP-E
RAS-M10SKCVP-E, M13SKCVP-E
RAS-B16SKVP-E, M16SKCVP-E
Z
Attachment bolt arrangement of outdoor unit
• Secure the outdoor unit with the attachment bolts and
nuts if the unit is likely to be exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
If it is necessary to drain the defrost water, attach drain
nipple to the base plate of the outdoor unit before
installing it.
10-2-2. Accessory and Installation Parts
Part No.
Part name (Q'ty)

Installation plate × 1
Wireless remote controller × 1
ƒ
AAAA Battery × 2
This model is not equipped with an extension drain hose.
Option:
For the extension drain hose, use the optionally available RB-821SW or a commercially available one.
• Indoor units connectable with a multi-system outdoor unit (Other indoor units are unavailable.)
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E,
RAS-M10SKCVP-E, RAS-M13SKCVP-E, RAS-M16SKCVP-E
• When using a multi-system outdoor unit, refer to the installation manual provided with the model
concerned.
Refrigerant piping
Liquid side (Outer diameter)
Shield pipe (for extension drain hose) (polyethylene foam, 6 mm thick)
Part No.
Remote controller holder × 1
Mounting screw Ø4 × 25L × 6
Parts name
6.35 mm
6.35 mm
Elongated
( 11 )
drain hole
Part name (Q'ty)
Plasma pure filter × 1
– 58 –
Gas side (Outer diameter)
9.52 mm
12.7 mm
600
Suction side
115 125
50
30
Drain hole
Diffuser
( 10 )
Part No.
Part name (Q'ty)
Remote controller
holder mounting screw
Ø3.1 × 16L × 2
<Others>
Name
Owner's manual
Installation manual
Important information
and warning*
B/W strips*
(Energy efficiency labels)
Q'ty
1 ea.