Toshiba RAS-B10SKVP-E Service Manual page 26

Split type
Hide thumbs Also See for RAS-B10SKVP-E:
Table of Contents

Advertisement

RAS-M10SKCVP-E, RAS-M13SKCVP-E, RAS-M16SKCVP-E / RAS-3M18SACV-E
To
C room
Connecting pipe
Thickness : 0.8 mm
9.52 :
RAS-M10SKCVP-E
RAS-M13SKCVP-E
12.7 :
RAS-M16SKCVP-E
Pressure
P
measurement
Gauge attaching port
Vacuum pump
connecting port
Accumulating tank
54 370
Temp. measurement
NOTE :
• The maximum pipe length of this air conditioner is 50 m. The additional chaging of refrigerant is unneces-
sary because this air cinditioner is designed with charge-less specification.
• Never connect one indoor unit only. Two or more indoor units should be connected.
INDOOR UNIT A
To
B room
Connecting pipe
Thickness : 0.8 mm
6.35
( 9.52)
( 9.52)
( 9.52)
TGc
TGb
TGa
TD
Compressor
DA130A1F-25F
Outdoor heat
exchanger
T
2
Propeller fan
OUTDOOR UNIT
Temp. measurement
T1
To
Indoor heat
C room
exchanger
Cross flow fan
Sectional shape
of heat insulator
TO
– 26 –
To
B room
( 6.35)
( 6.35)
( 6.35)
Strainer
Pulse motor valve
at liquid side
(UKV-18D64)
Refrigerant amount : 1.5kg (R410A)
NOTE :
Gas leak check position
Refrigerant flow
Per 1 unit
Max. : 20m
Min. : 2m
Total
Max. : 50m

Hide quick links: