AERATION ADJUSTMENT

The burner aeration is factory set. Adjustment may be needed
due to the local gas supply or altitude. As a general rule if the flame
is too yellow open up the air shutter, if it is too blue close the air
shutter.
NG 11 mm
LPGwide open
Note: This adjustment only to be made by an authorised
person.

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct flame pattern
has three strong blue flames: 1 flowing around the thermo-
pile, 1 around the thermocouple and 1 flowing across the
burner (it does not have to be touching the burner).
Note:
If you have an incorrect flame pattern, contact your
Regency dealer for further instructions.
Top View of pilot flame
Incorrect flame pattern will have small, probably yellow
flames, not coming into proper contact with the rear burner
or thermopile or thermocouple.
Top View of pilot flame
Regency F33-1 Freestanding Gas Stove

THERMOPILE/THERMOCOUPLE

REPLACEMENT
1)
Loosen the thermocouple or thermopile with a 9mm span-
ner at bracket.
2)
Disconnect thermocouple by loosening nut from the valve
with a 9mm spanner. Disconnect thermopile by loosening
2 screws marked TP on the valve.
3)
Drop the thermocouple or thermopile down from the brack-
et and pull it out of the unit.
4)
Reinstall the new ones in reverse order.

REMOVING VALVE ASSEMBLY

1)
Shut off gas supply.
2)
If optional fan is installed, disconnect power source to
stove.
3)
Remove access panel.
a) Front panel on pedestal model. See diagram 1.
b) Panel from bottom of leg shield. See diagram 2.
Note: Access panel only has to be loosened to be taken
out.
Diagram 1
Diagram 2
MAINTENANCE