Installation Manual Reprint; Sel-1200 (Option) - Vertex Standard VX-1210 Service Manual

Hide thumbs Also See for VX-1210:
Table of Contents

Advertisement

Installation
r Make sure that the transceiver is off. Remove the Battery
Pack, Microphone, and Antenna from the transceiver.
r Referring to Figure 1, remove the two screws from the left
side of the transceiver.
r Referring to Figure 2, remove the five screws from the rear
panel of the transceiver.
r Draw off the rear panel and case from the transceiver body.
r Referring to Figure 3 & 4, connect the supplied connection
cable between J
on the MAIN U
1017
CNTL U
, then route the connection cable as shown in the
NIT
drawing.
r Affix the SEL-1200 SELCALL Unit onto the MAIN U
using the supplied double-sided adhesive tape, then connect
the 3-pin plug from the SEL-1200 to J
U
(Figure 4).
NIT
r Replace the case and rear panel with its seven screws, using
care to avoid pinching or damaging the connecting wires and
wounding the MIC jack.
r Connect the Battery Pack to the transceiver.
Figure 1
Figure 2
I
MPORTANT
Do not touch the potentiometer nor the jumper plug of
the SEL-1200. The SEL-1200 is carefully aligned at
the factory for the specified performance.
SEL-1200 I
NSTALLATION
and J
on the
2013
NIT
NIT
on the MAIN
1013
N
!
OTE

Installation Manual Reprint

M
ANUAL
Programming
r Connect the Microphone Box and Programming Cable of the
SVC-1200 Service Kit to the computer's serial port and the
transceiver's MIC jack.
r Start the CE42 Programming Software, then upload the cur-
rent programming data from the transceiver via the "Read
CH Data" menu which appears when you press the ([ F4 ] :
Transfer ) key.
r Press the ([ F3 ] : Option ) key to invoke a pop-up window,
then select the "Sel Call Unit" item, and change its setting to
"on."
r Program the SELCALL features (such as the "Sel Call ID,"
,
"Sel Call Memory," etc.), if needed.
r Press the ([ F3 ] : Option ) key again to close the pop-up win-
dow, then turn on the SELCALL feature (on the main screen)
on the channel(s) where you wish to operate.
r Download the revised programming data to the transceiver
from the computer via the "Write CH Data" menu, which
appears when you press the ([ F4 ] : Transfer ) key.
r Installation and programming are now complete.
r Disconnect the Programming Cable from the transceiver's
MIC jack.
Supplied
Connection Cable
J
2013
CNTL UNIT
SEL-1200
Supplied
Connection Cable
MAIN UNIT
Figure 3
PA UNIT
J
1017
J
1016
Figure 4
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents