:'11/Jul/22
1
Main
Sub
code
code
L4
01
Content
Main motor lock detection
Detail
The main motor does not rotate.
After rotation of the main motor, the motor lock
signal is detected for 1 sec or more.
During rotation of the main motor, the motor
lock signal is detected for 1 sec.
When the main motor is stopped, the motor
lock signal is not detected for 5sec or more.
(Though the motor is stationary, it is judged as
stable rotation.)
Cause
Main motor unit abnormality
Improper connection or disconnection the main
motor and the harness.
MCU PWB abnormality
Check
Use SIM 25-01 to check the main motor
and
operations.
remedy
Check connection of the main motor harness/
connector.
Replace the main motor.
Replace the MCU PWB.
31
Content
Fusing fan lock detection
Detail
The fusing fan does not rotate.
Sampling is performed in 50msec interval, and
the normal signal cannot be detected 5 times
continuously in 1 sec.
Cause
Fan trouble or harness contact trouble and
disconnection
Check
Use SIM05-02 to check the operations of the
and
fusing fan motor.
remedy
Heck connection of the fan harness and the
connector.
Replace the fan.
Replace the MCU PWB.
32
Content
PSFAN lock detection
Detail
The PSFAN does not rotate.
Sampling is performed in 50msec interval, and
the normal signal cannot be detected 5 times
continuously in 1 sec.
Cause
Fan trouble or harness contact trouble and
disconnection
Check
Check connection of the fan harness and the
and
connector.
remedy
Replace the fan.
Replace the MCU PWB.
L6
10
Content
Polygon motor lock detection
Detail
The polygon motor does not rotate
After beginning to rotate the polygon motor, the
1
motor lock signal is detected for 20sec or more.
During rotation of the polygon motor, the motor
lock signal is detected for 1sec.
Cause
Polygon motor unit abnormality
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality
Check
Use SIM 61-3 to check the polygon motor
and
operations.
remedy
Check connection of the polygon motor
harness/connector.
Replace the polygon motor..
Replace the MCU PWB.
Details of trouble
AR-5618S TROUBLE CODE LIST 8-4
Main
Sub
code
code
U2
04
Content
EEPROM read/write error (Serial
communication error)
Detail
EEPROM access process error
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
11
Content
Counter check sum error (EEPROM)
Detail
Check sum error of the counter area in the
EEPROM
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
12
Content
Adjustment value check sum error (EEPROM)
Detail
Check sum error of the adjustment value area
in the EEPROM
Cause
EEPROM abnormality
Check
Check that the EEPROM is properly set.
and
Use SIM 16 to cancel the trouble.
remedy
Replace the MCU PWB.
CH
None Content
Side door open
ON
Detail
The side door is open.
Cause
Side door sensor abnormality
MCU PWB abnormality
Check
Check that all the side doors are closed.
and
Replace the MCU PWB.
remedy
CH
None Content
Developing cartridge not installed
Blink
Detail
The developing cartridge is not installed.
Communication with the CRUM cannot be
made in initial check of the CRUM.
Cause
Developing unit disconnection
MCU PWB abnormality
CRUM chip abnormality
Check
Check installation of the developing unit.
and
Replace the MCU PWB.
remedy
Details of trouble