Sharp AR-5618 Service Manual page 36

Digital multifunctional system
Table of Contents

Advertisement

Main
Sub
Contents
code
code
10
-
Toner motor operation
14
-
Trouble cancel (except for U2)
16
-
U2 trouble cancel
20
01
Maintenance counter clear
21
01
Maintenance cycle setting
02
Mini maintenance cycle setting
(Valid only when the destination is
set to Japan AB series.)
22
01
Maintenance counter display
02
Maintenance preset display (Valid
only when the destination is set to
EX Japan)
03
Jam memory display
04
Jam total counter display
05
Total counter display
06
Developing counter display
07
Mini maintenance preset display
(Valid only when the destination is
set to Japan AB series)
08
SPF counter display
09
Paper feed counter display
12
Drum counter display
13
CRUM destination display
When the [START] key is pressed, the toner motor is driven for 30 sec.
After completion of the process, the machine goes into the main code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the main code input standby mode.
*
Trouble to write into the EEPROM such as H trouble is canceled and hardware reset is
performed.
*
U2 trouble is canceled and hardware reset is performed.
When the [START] key is pressed, the maintenance count value is cleared and "000000" is
displayed. (Alternate display of "000" and "000")
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
Code
0
1
2
3
4
5
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
Code
0
1
2
The maintenance counter value is displayed.
The copy quantity corresponding to the code that is set with SIM21-01 is displayed.
(For example: 50,000 sheets)
The LED of the latest jam position is lighted. Every time when the [PRESET RATIO selector] keys is
pressed, the jam memory data is acquired sequentially from the latest. The jam position is judged by
the acquired data and the corresponding LED is lighted. The 7-seg display indicates the jam number.
At that time, "A" is displayed on the upper first digit. When the last one is displayed, the latest one will
be displayed again. Max. 30 jams from the latest are stored. When the [Interrupt] key is pressed, the
machine goes into the sub code input standby mode. When the [CA] key is pressed, the simulation is
terminated.
The jam total counter value is displayed.
The total counter value is displayed.
The developing counter data is acquired and displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The mini maintenance cycle data is acquired and displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The SPF counter value is displayed.
The counter value of the selected paper feed section is acquired from each variable, the data is
displayed on the 7-seg display according to the regulations. When this simulation is executed, the
value of the 1st paper tray is displayed first. Press the [TRAY SETTING] key to select the tray. When
the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The drum counter and the drum rotating time are displayed.
To change the display mode, press the [AUTO/TEXT/PHOTO] key.
LED
AUTO exposure indicator
TEXT indicator
When this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed.
This simulation is valid only for the models where the CRUM is valid.
7-seg display
Meaning (CRUM destination)
00
Not set yet
01
BTA-A
02
BTA-B
03
BTA-C
AR-5618S SIMULATIONS 7-6
Details of operation
Setting
5,000 sheets
7,500 sheets
10,000 sheets
25,000 sheets
50,000 sheets
* Default
Free (999,999 sheets)
Setting
5,000 sheets
* Default
10,000 sheets
Free (999,999 sheets)
Drum counter
Drum rotating time
7-seg display
04
05
06
99
Display mode
Meaning (CRUM destination)
CHN-A
JPN_A
BTA_F
Conversion

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-5623Ar-5620Ar-5620sAr-5618nAr-5618sAr-5620n ... Show all