Advertisement

5 E m e r g e n c y K e y s a n d A l a r m s
If the Carbon Monoxide Alarm Sounds
1. Operate Silence button.
2. Call emergency services or your fire department.
3. Immediately move outdoors or to an open door/window.

5.2.3 Intrusion (Burglary) Alarm - Continuous Siren

!
If you are unsure of the source of the alarm approach with caution!
If the Intrusion alarm was accidental
1. Enter your Access Code to silence the alarm. If the code is entered within 30s (or the programmed
value of the alarm transmission delay) the transmission of the alarm to the monitoring station will be
cancelled.
2. Call your central station to avoid a dispatch.

5.2.4 Alarm Cancel Window

The control panel provides a period of time in which the user can cancel the alarm transmission. The
minimum duration of this time is five minutes.
If the programmed alarm transmission delay has expired, cancelling an alarm sends a message to the
monitoring station. Upon a successful transmission of the cancellation message the keypad will beep 6
times.
NOTES:
Must be enabled and configured by installer.
For CP-01 systems, alarm transmission delay must not exceed 45 seconds.

5.3 Resetting Smoke Detectors

After having detected an alarm condition smoke detectors require a reset to exit the alarm condition.
NOTE:
Verify with your alarm company if this function is required on your system.
To Reset the Sensors
• Press and hold
• If a smoke detector fails to reset, it may still be detecting an alarm condition. If unsuccessful, the alarm
will reactivate or continue.

5.4 Viewing Alarms in memory

When an alarm occurs the keypad indicator illuminates. Viewing the Alarm memory provides more
information on the sensor(s) that were tripped. When using a ICN or LED keypad the Memory LED
will be lit and the zone numbers will be displayed.
To View Alarms in Memory
*
• Press
3
OR
use the scroll keys
The Alarm information will display. For more information on the messages
that could be displayed see 5.4.1 "Alarm Messages".

5.4.1 Alarm Messages

LCD Display
Burglary
<>
Verified
on the keypad for 2 seconds. If the reset is successful, the alarm is cancelled.
to navigate to Alarm Memory and press
What it means
Multiple burglary sensors were tripped. Central station has been notified.
21
LCD Display
Press (*) for <>
Alarm Memory
*
.