Download Print this page

NAPCO WI850A GEM-P800 Installation Instructions Manual page 8

Hide thumbs Also See for WI850A GEM-P800:

Advertisement

WI850A GEM-P800 Installation Instructions
Keypad LEDs
ARMED LED DEFINITION
Armed
Instant Mode
Zone in Alarm
STATUS LED DEFINITION
Ready to be Armed
Zone faulted
 
TROUBLE LED DEFINITION
AC Failure
System Trouble(s)
 
FIRE LED DEFINITION
Fire Alarm
Fire Memory/*Fire Trbl
*See Note 1
AC LED DEFINITION
AC Present
AC Failure
ZONE LED DEFINITION
Faulted Zone
Bypassed Zone
Zone in Alarm
N
:
OTE
* If Fire Trouble on Fire LED [96-4] has been enabled, a steady
Fire LED will indicate Fire Trouble.
8
3DQHO 2SHUDWLRQ
Arming (System ON)
ON
Before arming the system close all protected
Rapid Flash
zones (unless programmed as Auto-Bypass
Flashing
Reentry Zones).
code, followed by the
provide a feedback beep for each key pressed.
ON
If a valid Arm/Disarm code is entered, the
OFF
keypad will beep 3 times. If an incorrect Arm/
Disarm code is entered, the keypad will sound
a 1-second tone indicating an incorrect entry.
Flashing
ON
Arming without Entry Delay (Instant
Mode)
Enter the
The ARMED LED will flash rapidly to indicate
Flashing
the panel is in Instant Mode. If an Exit/Entry
ON
Zone is tripped while the panel is in Instant
Mode the panel will go into alarm immediately.
ON
Arming/Disarming with a Keyfob
OFF
The system can be armed by pressing the
key, and disarmed by pressing the
the Keyfob. Zones programmed as Exit/Entry
ON
Follower Zones can be bypassed when the
Slow Flash
or
Flashing
grammed for Interior [81-84].
grammed as Home /Away with Delay Zones can
be armed regardless of the state of the Exit/
Entry Zones when the
Enter a 4-digit Arm/Disarm

key, the keypad will

key to eliminate the entry delay.

keys on the Keyfob have been pro-

Zones pro-
or
keys on the


Keyfob have been programmed for
[81-84]. To arm the system with all zones pro-
tected press the
or
key for 1.5s to fully set the system
(The LED on the Keyfob indicate the Keyfob has
transmitted the signal).
Keyswitch Chirp [23-4] for an audible indication
of system arming and disarming.
Arming/Disarming with a Keyswitch
The system can be armed/disarmed by using a
momentary Keyswitch wired to Zone 6. Program
Keyfob/Keyswitch Chirp [23-4] for an audible
indication of system arming and disarming.
N
:
OTE
Faulted Keyswitch or silent 24 hour zone normally do not
display at the keypad. If a silent 24 hour zone or Keyswitch
is faulted at the time of arming the faulted zone will display
only while the priority sound is ON.


Arming Instant with a Keyfob
The panel can be ARMED INSTANT when the

or
keys on the Keyfob have been
key on
Instant [81-84]. To arm the
programmed for
system with Instant protection press the
key, then press and hold the
1.5s to arm the panel with INSTANT protection.
Disarming (System OFF)
After entering the premises through an Exit/Entry
Zone, the keypad will sound the Entry Delay
Full Set
key. Press and hold the
Program Keyfob/


or
key for

Advertisement