5.
The pilot and main burner
extinguish while in operation.
6. Glass soots.
5.
Flame burns blue and lifts off
burner.
a.
No L.P. in
tank.
b.
Inner fl ue pipe leaking exhaust
gases back into system.
c.
Glass too loose and air tight,
gasket leaks in corners after
usage.
d.
Horizontal fl ue improperly
pitched.
e.
Bad thermopile or thermo-
couple.
f.
Improper fl ue cap installation.
a. Flame impingement on logs.
b. Improper venturi setting.
c. Debris around venturi.
a.
Insuffi cient oxygen being
supplied
Heat & Glo • ATS-AU-D • 327-900 Rev. F • 6/09
Check L.P. (Propane) tank. Refi ll fuel tank.
Check for leaks.
Be certain glass assembly is installed correctly and tighten corner.
The horizontal fl ue cap should slope down only enough to prevent any
water from entering the unit. The maximum downward slope is 1/4 inch.
Replace if necessary.
Check for proper installation and freedom from debris or blockage.
Adjust the log set so that the fl ame does not excessively impinge on it.
Adjust the air shutter at the base of the burner.
Inspect the opening at the base of the burner. It is imperative that NO
material be placed in this opening.
Check to make sure fl ue cap is installed properly and free of debris. Make
sure that fl ue system joints are tight and have no leaks.
Check to make sure that no material has been placed at the burner base.
Be sure glass is tightened properly on unit, particularly on top corners.