Positioning - Viessmann Vitolig 200 Technical Manual

Solid fuel boiler 5 to 40 kw
Table of Contents

Advertisement

5 Vitolig 100
FR
Legends
AGA Flue pipe
E
Drain and diaphragm expansion
vessel
FR
Combustion control unit
KR
Boiler return

5.2 Positioning

200
428
100
56
KTH
AGA
KTH Boiler thermometer
KV
Boiler flow
KW
Cold water inlet at the safety heat
exchanger
SA
Safety connection
(safety valve)
H No air contamination through
halogenated hydrocarbons (e.g. as
contained in sprays, paints, solvents
and cleaning agents).
H Avoid very dusty conditions
H Avoid high levels of humidity
H Avoid danger of freezing and ensure
good ventilation.
Otherwise the system may suffer faults
and damage.
The boiler may only be installed in rooms
where air contamination through
halogenated hydrocarbons may occur,
such as through hairdressing salons,
printing shops, chemical cleaners,
laboratories etc., if adequate measures
can be taken to provide uncontaminated
combustion air.
If in doubt, please contact us.
If these instructions are not observed, any
consequential losses directly related to
any of these causes, are excluded from
our warranty.
KV1/SA
KW
KV2
TAS
WW
TR
100
KR1
KR2
E
Overall width
556
Overall length
TAS Coupling R ½" for the probe of the
thermostatic drain
TR
Control thermostat
WW Cold water outlet of the safety heat
exchanger (no DHW connection)
Top−mounted oil /gas fired boiler
An assembly set, comprising two
mounting rails, is available as accessory
for mounting one Vitola or Vitorond oil−
or gas−fired boiler on to of the Vitolig 100
(see price list).