Specification - Viessmann Vitolig 200 Technical Manual

Solid fuel boiler 5 to 40 kw
Table of Contents

Advertisement

4 Vitolig 200

4.1 Specification

Rated output range
Permissible flow temperature
Minimum return temperature
Max. operating pressure
Boiler
Heat exchanger
CE designation
In accordance with the
Pressure Vessel Guideline
Boiler class acc. to EN 303 5
Overall dimensions
Overall length
Overall width
Overall height
Transport dimensions
with transport protection
Length
Width
Height
Total weight
Boiler shell with thermal insulation
Weight
boiler body
Max. elec. power consumption
Contents
Boiler water
Fuel hopper
Boiler connections
Boiler flow and return plus
safety connection
(safety valve)
Drain
Heat exchanger connections
Cold water, hot water
Primary side
Flow resistance
DT = 20 K
DT = 10 K
*1
Flue gas
(at higher output)
Medium temperature (gross
Mass flow rate
CO
content in the flue gas
2
Flue outlet
Required draught
*1
Values for calculating the size of the flue system, according to DIN 4705 based on 10.0 % CO
Flue gas temperature measured as average gross value as per EN 304 at 20 ºC combustion air temperature.
*2
30
kW
ºC
ºC
bar
bar
mm
mm
mm
mm
mm
mm
kg
kg
W
litres
litres
G (female thread)
R (male thread)
R (male thread)
mbar
mbar
*2
) ºC
kg/h
%
External ∅ mm
Pa
mbar
13 to 26
100
45
3
6
CE 0036
3
1 014
915
1 493
1 045
790
1 545
580
543
120
71
150
1¼"
½"
¾"
0.9
6.0
160
65
13
160
13
0.13
.
2
20 to 40
100
45
3
6
3
1 014
915
1 693
1 045
790
1 745
650
629
120
93
215
1¼"
½"
¾"
3.4
19.5
175
105
13
160
15
0.15