Specifications; General Description - Panasonic KX-TDA100D Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100D:
Table of Contents

Advertisement

1.3.1 General Description

1.3 Specifications

1.3.1 General Description
Control Bus
Communication Bus
Switching
Power Input
External Battery
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Conference Call Trunk
Music on Hold (MOH)
Paging
Serial Interface
Port
Extension Connection Cable
Dimension
20
Installation Manual
Original bus (16-bit, 8 MHz, 10 megabytes per second)
H.100 bus conformity (1024 time slots)
Non-blocking
100 V AC to 130 V AC; 2.8 A/200 V AC to 240 V AC; 1.7 A; 50
Hz/60 Hz
+36 V DC (+12 V DC ´ 3, recommended maximum capacity is
28 Ah)
300 ms (without using backup batteries)
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 W maximum
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
From 10 ´ 3-party conference call to 4 ´ 8-party conference call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (maximum 115.2 kbps)
USB
1
SLT
DPT
PT-interface CS
PT-interface CS (High-density)
DSS Console and Add-on Key
Module
334 mm (W) ´ 390 mm (H) ´ 270 mm (D)
1-pair wire (T, R)
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
1-pair wire (D1, D2)
4-pair wire (D1, D2)
1-pair wire (D1, D2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents