Snmp > Rmon > Rmon History; Snmp > Rmon > Rmon Alarm - D-Link DES-1210-08P Reference Manual

Des-1210 series web smart switch
Hide thumbs Also See for DES-1210-08P:
Table of Contents

Advertisement

4 Configuration
DES-1210 Series Switch Web UI Reference Guide
Index (1 - 65535): Indicates the RMON Ethernet Statistics entry number.
Port: Specifies the port from which the RMON information was taken.
Owner: Displays the RMON station or user that requested the RMON information.
Click Add to make the configurations take effects and click Refresh to redisplay the information.
SNMP > RMON > RMON History
The RMON History Control Configuration page contains information about samples of data taken from ports.
For example, the samples may include interface definitions or polling periods.
Figure 4.124 – SNMP > RMON > RMON History
The History Control Configuration contains the following fields:
Index (1 - 65535): Indicates the history control entry number.
Port: Specifies the port from which the RMON information was taken.
Buckets Requested (1 ~ 50): Specifies the number of buckets that the device saves.
Interval (1 ~ 3600): Indicates in seconds the time period that samplings are taken from the ports. The field
range is 1-3600. The default is 1800 seconds (equal to 30 minutes).
Owner: Displays the RMON station or user that requested the RMON information.
Click Add to make the configurations take effects.
SNMP > RMON > RMON Alarm
The RMON Alarm Settings page allows the user to configure the network alarms. Network alarms occur
when a network problem, or event, is detected.
Figure 4.125 – SNMP > RMON > RMON Alarm
The configuration contains the following fields:
Index (1 - 65535): Indicates a specific alarm.
Variable: Specify the selected MIB variable value.
Rising Threshold (0 ~ 2^31-1):
Displays the rising counter value that triggers the rising threshold alarm.
Rising Event Index (1 ~ 65535):
Displays the event that triggers the specific alarm. The possible field values are
user defined RMON events.
Owner:
Displays the device or user that defined the alarm.
8
1
8
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Des-1210-28Des-1210-28pDes-1210-52

Table of Contents