Programing Options; General Specifications - Hellenbrand H-150 Series Owner's Manual

Water conditioning system with hp electronics
Hide thumbs Also See for H-150 Series:
Table of Contents

Advertisement

Reserve
Regeneration
Gallons
Type
AUTO
Delay
AUTO
Delay
20 to
Delay
250,000
Delay
oFF
20 to
Delay
250,000
Immediate
AUTO
20 to
Immediate
250,000
AUTO
Delay + Immediate
Delay + Immediate
AUTO*
20 to
Delay + Immediate
250,000
*Factory settings in bold
To "lockout" access to modification settings, diagnostic and valve history displays except hardness, day overide and time,
press
X
next,
X
OPERATING PRESSURES
Minimum/Maximum ..................................................................................................................................25 psi-125 psi
OPERATING TEMPERATURES
Minimum/Maximum ..................................................................................................................................40º - 110º F
METER
Accuracy ...................................................................................................................................................±5%
Flow Rate Range......................................................................................................................................0.5 - 60 GPM
Gallon Range ...........................................................................................................................................500 - 250,000
DIMENSIONS
Drain Line .................................................................................................................................................3/4" or 1" NPT
Brine Line .................................................................................................................................................1/2" Poly Tube
Electrical Current Draw and Voltage ........................................................................................................0.5A 110v
Compatible with the following regenerants or chemicals: Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide,
hydroxide, hydrochloric acid, chlorine and chloramines.
34
proGraMMinG opTions
Days
Override
oFF
Reserve capacity automatically estimated.
1 to 28
Regeneration occurs at the next Regen Set Time when gallons capacity falls below the
reserve capacity or the specified number of days between regenerations is reached.
oFF
1 to 28
1 to 28
oFF
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
oFF
capacity at the next Regen Set Time or regeneration occurs immediately after
10 minutes of no water usage when gallon capacity reaches 0.
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
1 to 28
falls below the reserve capacity or the specified number of days between regenerations
*14
is reached or regeneration occurs immediately after 10
minutes of no water usage when gallon capacity reaches 0.
1 to 28
and clock in sequence to "unlock" press

General speCifiCaTions

Results
(Reserve capacity estimate based on history of water usage)
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at the next
Regen Set Time.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of days
between regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the
specified number of days between regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration will always
occur when gallons capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration will always
occur on 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when specified number of days
between regenerations is reached or regeneration occurs immediately after 10 minutes
of no water usage when gallon capacity reaches 0.
X
next,
z
and clock in sequence.