Head Side Select Options S1--S3; Spindle Motor Control Options; Motor Control Select Options Mc1--Mc4 - Tandon TM848-1 Operating And Service Manual

Oem disk drives 48 tracks per inc
Hide thumbs Also See for TM848-1:
Table of Contents

Advertisement

Note
This option does not stop the write protect signal from being sent on the interface line.
This option is implemented by cutting WP, and by installing NP.
1.19.20
Head Side Select Options S1--S3
This option allows heads to be selected by side select, drive select, orthe direction control signal. The
drive comes with side select, S2, installed.
To use the drive select line to enable the heads, cut S2 and install S3 along with the proper 18-48
jumper that is used with S3 (see 18-48). For head selection using Direction Select, cut S2, and install
S1.
1.19.21
Spindle Motor Control Options M 1--M4
M 1 is used to enable the motor off delay timer. When this jumper is installed, the drive motor is
enabled and disabled by either the drive select (M3) or head load (M4) commands. A 20-second turn
turn off delay of the spindle motor is activated on the trailing edge of the controlling signal.
M2 is used for radial motor control independent ofthe motor control functions installed with M 1, M3,
and M4.
M2 should be in ifthe user wishes to enable the drive motor continuously or to use the radial motor on
line MC1-MC4.
M3 is used to control the drive motor using drive select. When the drive select line goes low (true), the
drive motor comes up to speed in less then 500 milliseconds and becomes ready in less than 700
milliseconds. After the drive select line goes false (high), the motor will run for 20 seconds. To
implement this option, install a jumper at location M3. For correct operation of M3, remove M4.
M4 is used to start the drive motor using the head load interface lines. When the head load line goes
low (true), the drive motor comes up to speed in less than 500 milliseconds and becomes ready in less
than 700 milliseconds. After the head load line goes high (false), the motor will run for 20 seconds. To
implement this option, remove M3 for correct operation of option M4.
1.19.22
Motor Control Select Options MC1--MC4
This option is used if the drive motor is to be enabled independent of drive select or head select. When
these lines are low (true), the motor is off. The drive comes without this option installed. This option
does not operate the time out delay circuit.
To implement this option that controls the drive motor using an MCx line, install the appropriate MC 1-
MC4 jumper. When using this option, M2 must be installed. If the motor turn off delay is desired, the
delaycan be triggered by Drive Select or Head Load commands, when used in conjunction with M3 or
M4.
1-22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm848-2

Table of Contents