Download Print this page

Device Information; Performance Data - Dimplex SIH 6ME Installation And Operating Instructions Manual

Brine-to-water heat pump for indoor installation

Advertisement

Available languages

Available languages

12

12 Device Information

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation Location
3

Performance data

3.1
Operating temperature limits:
1
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
3.6
Brine throughput with an internal pressure
differential (heat source) of
3.7
Refrigerant; total filling weight
3.8
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. For brine temperatures between -5 °C and 0 °C, flow temperature increasing from 65 °C to 70 °C
2. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
3. Note that additional space is required for pipe connections, operation and maintenance.
4. See CE declaration of conformity
5. The heat circulating pump and the heat pump controller must always be ready for operation.
E-8
°C
°C
at B0 / W35
K
2
at B-5 / W55
kW / ---
2
at B0 / W45
kW / ---
2
at B0 / W50
kW / ---
2
at B0 / W35
kW / ---
dB(A)
m³/h / Pa
type / kg
type / litres
3
H x W x L mm
Inch
Inch
kg
V / A
2
B0 W35
kW
A
A / ---
5
SIH 6ME
SIH 9ME
IP 20
IP 20
Indoors
Indoors
70±2
70±2
-5 to +25
-5 to +25
Mono-ethylene glycol
Mono-ethylene glycol
25%
25%
10.,6
5.0
10.3
4.9 / 2.2
7.9 / 2.2
5.7 / 3.2
5.8 / 3.0
8.9 / 3.1
6.2 / 4.3
6.0 / 4.1
9.1 / 4.2
56
56
0.5 / 1200 1.0 / 4100 0.76 /1700 1.55 / 6400 1.0 / 1600 1.9 / 7000
1.30 /8900 1.30 /8900 2.0 / 7500 2.0 / 7500 2.45 /8000 2.45 / 8000
R134a / 1.8
R134a / 2.2
Polyolester (POE) /
Polyolester (POE) /
1.1
1.95
805 × 650 × 462
805 × 650 × 462
G 1¼" a
G 1¼" a
G 1¼" a
G 1¼" a
118
130
230 / 20
230 / 25
1.44
1.47
2.17
38
43
9.2 / 0.8
9.3 / 0.8
11.1 / 0.8
4
4
Yes
Yes
1
1
Internal
Internal
SIH 11ME
IP 20
Indoors
70±2
-5 to +25
Mono-ethylene glycol
25%
5.0
9.3
5.0
8.9 / 2.5
9.6 / 3.27
10.0 / 3.5
10.3 / 3.3
8.9 / 4.0
10.8 / 4.6
10.7 / 4.5
57
R134a / 2.4
Polyolester (POE) /
1.90
805 × 650 × 462
G 1¼" a
G 1¼" a
133
230 / 32
2.22
2.34
2.36
45
11.2 / 0.8
12.4 / 0.8
12.4 / 0.8
4
Yes
1
Internal

Hide quick links:

Advertisement

loading