Dimplex SIH 4ME Installation And Operating Instructions Manual

Dimplex SIH 4ME Installation And Operating Instructions Manual

Brine-to-water heat pump for indoor installation

Advertisement

SIH 4ME
SIH 6ME
SIH 9ME
SIH 11ME
Brine-to-Water
Heat Pump for
Indoor Installation
Installation and
Operating Instructions
8/60183/0
ISSUE 2

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex SIH 4ME

  • Page 1 SIH 4ME SIH 6ME SIH 9ME SIH 11ME Installation and Operating Instructions Brine-to-Water Heat Pump for Indoor Installation 8/60183/0 ISSUE 2...
  • Page 2: Table Of Contents

    Table of contents Please Read Immediately.........................2 1.1 Important Information..........................2 1.2 Intended Use.............................. 2 1.3 Legal Regulations and Directives ......................2 1.4 Energy-Efficient Use of the Heat Pump ..................... 2 Purpose of the Heat Pump .......................3 2.1 Application ..............................3 2.2 Operating Principle ............................
  • Page 3: Please Read Immediately

    Please Read 1.2 Intended Use Immediately This device is only intended for use as specified by the manufac- turer. Any other use beyond that intended by the manufacturer is prohibited. This requires the user to abide by the manufacturers 1.1 Important Information product information.
  • Page 4: Purpose Of The Heat Pump

    Purpose of the Heat Basic Device Pump The basic device consists of a ready-to-use heat pump for indoor installation, complete with sheet metal casing, control panel and integrated heat pump manager. The refrigerant circuit is hermet- 2.1 Application ically sealed. It contains the Kyoto protocol approved refrigerant R134a with a GWP value of 1300.
  • Page 5: Accessories

    Accessories 4.4 Thermal energy meter WMZ 4.4.1 General description 4.1 Brine Circuit Manifold The thermal energy meter (WMZ 25/32) is used for measuring The brine circuit manifold merges the individual collector loops of the quantity of thermal energy supplied. It is available as an ac- the heat source system into a single main pipe which is con- cessory.
  • Page 6: Transport

    Transport 6.2 Acoustic Emissions The heat pump operates silently due to efficient sound insulation. A lift truck is suited for transporting the unit on a level surface. To prevent noise transmission to the foundation, a suitable, Carrying straps may be used if the heat pump needs to be trans- sound dampening rubber mat should be placed underneath the ported on an uneven surface or carried up or down stairs.
  • Page 7: Heat Source Connection

    7.4.1 Sensor characteristic curves Minimum heating water flow rate The minimum heating water flow rate through the heat pump must be assured in all operating states of the heating sys- Temperature in °C tem. This can be accomplished, for example, by installing either Standard NTC-2 in 14.6 11.4...
  • Page 8: Electrical Connection

    7.5 Electrical connection 7.4.2 Mounting the external temperature sensor 7.5.1 General The temperature sensor must be mounted in such a way that all weather conditions are taken into consideration and the During start-up, observe the respective national safety regula- measured value is not falsified. tions and the applicable VDE safety regulations, particularly ...
  • Page 9: Commissioning

    8.3 Start-up Procedure The contactors mentioned above in points 3, 4 and 5 are in- stalled in the electrical distribution system. The mains cables The heat pump is started up via the heat pump manager. for the heating elements should be dimensioned and pro- tected according to DIN VDE 0100.
  • Page 10: Maintenance And Cleaning

    Maintenance and 10 Faults / Trouble- Cleaning Shooting This heat pump is a quality product and is designed for trouble- 9.1 Maintenance free operation. In the event that a fault should occur, it will be in- dicated on the heat pump manager display. Simply consult the To prevent faults due to sediment in the heat exchangers, care Faults and Trouble-Shooting page in the operating instructions of must be taken to ensure that no impurities can enter either the...
  • Page 11: Device Information

    12 Device Information Type and order code SIH 4ME SIH 6ME SIH 9ME SIH 11ME Design Degree of protection according to EN 60 529 IP 20 IP 20 IP 20 IP 20 Installation Location Indoors Indoors Indoors Indoors Performance data Operating temperature limits: 70±2...
  • Page 12: Appendix

    Appendix Dimension Drawings ........................A-II 1.1 Dimension Drawing..........................A-II Diagrams ............................A-III 2.1 Characteristic Curves SIH 4ME ......................A-III 2.2 Characteristic Curves SIH 6ME ......................A-IV 2.3 Characteristic Curves SIH 9ME ......................A-V 2.4 Characteristic Curves SIH 11ME ......................A-VI Circuit Diagrams .........................A-VII 3.1 Control ..............................
  • Page 13: Dimension Drawings

    1 Dimension Drawings 1.1 Dimension Drawing www.dimplexrenewables.co.uk A-II...
  • Page 14: Diagrams

    2 Diagrams 2.1 Characteristic Curves SIH 4ME A-III...
  • Page 15: Characteristic Curves Sih 6Me

    2.2 Characteristic Curves SIH 6ME www.dimplexrenewables.co.uk A-IV...
  • Page 16: Characteristic Curves Sih 9Me

    2.3 Characteristic Curves SIH 9ME...
  • Page 17: Characteristic Curves Sih 11Me

    2.4 Characteristic Curves SIH 11ME www.dimplexrenewables.co.uk A-VI...
  • Page 18: Circuit Diagrams

    3 Circuit Diagrams 3.1 Control A-VII...
  • Page 19: Load

    3.2 Load www.dimplexrenewables.co.uk A-VIII...
  • Page 20: Terminal Connection Plan

    3.3 Terminal Connection Plan A-IX...
  • Page 21: Legend

    3.4 Legend Wire jumper, must be inserted if no blocking contactor is fitted Wire jumper, must be removed if the 2nd disable contactor is used Wire jumper, must be removed if a motor protection contact is used for the primary pump Wire jumper, must be removed when a motor protection contact is used for the compressor Open wire jumpers or contacts mean: block or fault...
  • Page 22: Hydraulic Plumbing Diagram

    4 Hydraulic Plumbing Diagram 4.1 Monovalent heat pump system with three heating circuits and domestic hot water preparation A-XI...
  • Page 23: Legend

    4.2 Legend Check valve Shutoff valve Dirt trap Three-way mixer Circulating pump Expansion vessel Room temperature-controlled valve Shutoff valve with check valve Shutoff valve with drainage Safety valve combination Heat consumer Temperature sensor Flexible connection hose Check valve Brine-to-water heat pump Buffer tank connected in series Hot water cylinder Flange heater, hot water...
  • Page 24: Declaration Of Conformity

    Module A CE mark added: 2011 EC declaration of conformity issued on: July 2011 Issue: 1 Dimplex Renewables Subject to alterations and errors. +44 (0) 845600511 A division of the GDC Group Ltd www.dimplexrenewables.co.u Millbrook House, Grange Drive Hedge End, Southampton SO30 2DF...