Vermont Castings AVFL42NTSC Installation & Operating Instructions Manual page 23

Avfl vent free fireplace system
Table of Contents

Advertisement

TOUCH SCREEN REMOTE CONTROL OPERATION
Setting Privacy Code on Transmitter:
Figure 17
The remote transmitter privacy code
is preset in factory. In the event of
activation or interference from other
nearby transmissions, change the
code using the following procedures
(learn function must be performed af-
ter changing the code):
1. Press the ON/arrow button and
the TIMER button at the same
time to enter privacy code setup
models.
2. The setup display is shown in the
fi gure. The four digits on the top
stand for the privacy code. The default values of the
four digits will be all "0."
3. The fi rst digit will be fl ashing upon entering the setup
mode. Push the ON button to toggle its value between
"0" and "9," and push the "OFF" button to jump to the
next digit. The next digit will then start fl ashing and the
fi rst one stops fl ashing. Set up the four digits to your
choice between "0" and "9."
4. After setting up all the four digits, push "OFF" to fi nish
the process and return to the previous mode.
5. The Signature Command
re-learn the new setting.
Performing Learn Function
1. The RF receiver button on the control board in the fi re-
place must be in the on position before the learn func-
tion can begin. Figure 16. With the Command Center
master switch in the ON position, use paper clip to de-
press the recessed button on Control Board, one beep
for RF receiver ON or two beeps for RF receiver OFF.
2. Holding the OFF button on the Command Center while
turning on the master switch will activate the learn
function for the transmitter.
3. After the above op-
eration, two beeps
will sound and the
green LED on the
Command Center will
fl ash for 10 seconds.
4. During the 10 sec-
onds, press the OFF
button on the trans-
mitter to learn. Anoth-
er two beeps will be
sound confi rming a
successful learn func-
tion. Figure 19
20305467
Figure 17
control board then needs to
®
Figure 18
ON
LED
OFF
Battery Door
Figure 19 –
Command Center
Do not use two (2) or more remote control sys-
tems in the same area with the same privacy
code setting, as they will communicate with
each other. This may cause the appliances to
malfunction.
Resetting the transmitter:
If the transmitter is not working properly, reinstall the bat-
teries to reset the transmitter.
1. Pull out at least one of the batteries.
2. Press any key on the screen to discharge.
3. Wait for 10 seconds and reinstall the batteries.
Pushing and holding any key for more than 10 seconds
until the display refreshes will also reset the transmitter.
 Functions and Operations
General:
The TSFSC Remote Control has four (4) operating
modes: Manual, Timer, Thermostatic and Smart Mode.
The control system can be set to temperature range be-
tween 45° F and 90° F. The fl ame height can be adjusted
in the manual, timer and thermostatic mode. The Smart
Mode will automatically adjust fl ame height according to
the difference between Set and Room temperatures.
The transmitter will operate the remote receiver from 1
foot to a maximum of 30 feet. The distance is reduced
when batteries are low.
Manual Mode
Figure 20
In this mode, the TIMER button and the THERMO but-
ton will only display "TIMER" and "THERMO," respec-
tively without showing the time and the SET temperature.
Pressing the ON/up and OFF/down buttons will change
the fl ame height if none of the menu buttons (TIMER,
THERMO, LIGHT, FAN, AUX) are pressed and fl ashing.
1. Press the ON/up button to turn on the fi replace. The
fl ame icon on the LCD displays High.
AVFL Vent Free Fireplace
Master Switch
FP2650
Front Panel Bezel
(Optional)
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avfl42ptsc

Table of Contents