Functions/Operation - Vermont Castings AVFL42NTSC Installation & Operating Instructions Manual

Avfl vent free fireplace system
Table of Contents

Advertisement

SIGNATURE COMMAND SYSTEM OPERATION

FUNCTIONS/OPERATION

(from the Command Center)
Turning on the fi replace
1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center or turn
on wall switch. Pilot will light and burner will come on
High setting or last memory setting (See Turning Off
Fireplace below). For memory feature.
Pilot Safety Lockout Function
1. If the pilot doesn't light after sparking for 30 seconds, pilot
trial lockout happens. The LED on the Command Center
fl ashes Green once every 2 seconds, until reset.
2. If the pilot fl ame is lost during normal operation, the
system will try three (3) times to relight after three (3)
failures, fl ame loss lockout happens. The LED on the
Command Center fl ashes Red-Green once every 2
seconds, until reset.
3. Turning the master switch on the Command Center to
the off position, then ON again will reset the system.
Flame Height Control
1. Press the ON button (on the Command Center) once to
turn on the main burner with maximum fl ame height.
Command Center Operations:
The following functions are available on the Command Center.
FUNCTION
Power Up
Fireplace ON
Fireplace OFF
Flame Height Up
Flame Height Down
Self Diagnostics Chart:
The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a service
call. Please refer to the chart below for indicator reference.
FAULT
Conversion Cover Missing
Spark Fail
No Sensor Signal
Pilot Lockout – trial
Pilot Lockout – fl ame loss
Low Battery
No or Low Thermopile Power
Learning
AC Power On
Pressure Switch Failed (Power Vent only)
20305467
Flip the master switch to ON ("_") position to power up the system.
Press the ON  button on the Command Center or turn on wall switch.
Flip the master switch to the OFF ("o") position OR press the OFF  button 3
times OR for Memory Off, hold the OFF  button 3 seconds, or turn off wall switch.
Press the ON button once to turn on the fi replace with maximum fl ame height.
Press the OFF button to lower the fl ame height to Medium and Low.
2. Press the OFF button to decrease fl ame height. The fi rst
two presses will decrease the fl ame height to medium
and low.
3. The third press on OFF will turn off the main burner. In
standing pilot confi guration, the pilot will stay; in inter-
mittent pilot confi guration, the pilot will be shut off.
Turning the Off Fireplace
There are three ways to turn off the fi replace.
1. Flip the master switch to the off ("O") position. (This will
turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all last
settings before turning off. The next time the fi replace is
turned on, all settings will resume. To reset, change to
the desired settings and shut off by using the Memory
Off commands and the system will be reset to those
new settings.
NOTE: After turning off there may be up to a two (2)
minute delay before the burner can be relit. There will be
three (3) red fl ashes if the on button is pressed before
the safety control is automatically reset.
OPERATION
LED INDICATOR
One RED (1 time)
Two RED (1 time)
Three RED (1 time)
One GREEN, every 2 seconds until manual reset
One RED-GREEN every 2 seconds until manual reset
One RED every 10 seconds continuously
Two RED every 10 seconds continuously
GREEN fl ashes every 1 second for 10 seconds
GREEN solid
One RED every 2 seconds until manual reset
AVFL Vent Free Fireplace
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avfl42ptsc

Table of Contents