TOUCH SCREEN REMOTE CONTROL OPERATION
NOTE: there will a 10
second delay for the
fl ame adjustment when
the fi replace is turned
on.
1. When Set Temp. is
3° F or higher than
Room Temp., fl ame
height will be on High.
2. When Set Temp. is 2°
F higher than Room
Temp., fl ame height
will be on Medium.
3. When Set Temp. is 1°
F higher than Room
Temp., fl ame height
will be on Low.
4. When Set Temp. is equal to Room Temp., fl ame height
does not change (stays on low).
5. When Set Temp. is lower than Room Temp., the fi re-
place will be shut off.
6. When Set Temp. is 1° F higher than Room Temp.,
again the fl ame height will be on Low.
7. The fan speed follows the fl ame height, if the fan is
turned on.
To exit Smart Mode and shut off the fi replace;
a. push and hold the THERMO buttons for 3 seconds,
or
b. press the OFF button
or
c. slide down on the arrow buttons.
To shut off the Smart Mode option and return to regular
thermostat mode, press and hold the THERMO button
and the ON/UP button at the same time for 3 seconds
again.
Light Brightness Control
Figure 24
The light brightness control function is used to adjust the
brightness of the light bulbs con-
nected to the AC module on the
Signature Command
®
There are four light brightness
levels defi ned: Off, Low, Medium,
High
1. Press the LIGHT button to en-
ter the light brightness control
mode. The LIGHT icon will
start fl ashing.
2. Press the On/up and OFF/
down buttons to increase/
decrease the light brightness
(Off-Low-Medium-High).
20305467
Figure 23
System.
Figure 24
3. Press the light button again to confi rm the setting. The
new setting will be transmitted to the receiver.
4. After the signal is sent, the On/up and Off/down but-
tons become fl ame height controller again.
Smart
5. When the light button is fl ashing, slide up and down on
Mode
the arrow buttons will turn the light brightness to HIGH
Icon
or Off directly without pressing the light button again to
confi rm.
AUX Control
The AUX control function is used to turn on or
turn off the auxiliary component connected to
the AC module of the Signature Command
System. Press the AUX button to turn on or turn
off the auxiliary.
1. When the auxiliary is turned on, the icon will
become solid text and the "ON" icon will ap-
pear below the "AUX" icon.
2. When the auxiliary is turned off, the icon will become
hollow text and the "ON" icon will disappear.
NOTE: Some fi replaces use the AUX function to control
options within the fi replace. Refer to fi replace manual for
operation.
Setting up Blank Screen or Constant Display in Idle
Figure 23
There is an option
to set up how the
LCD displays and
functions when the
transmitter
is
idle. There are two
choices:
1. A) Mode. When
the transmitter is
in idle, the icons
in
the
"touch
area"
(timer,
t h e r m o s t a t ,
blower, light and
AUX) will disappear, as shown in the fi gure on the left.
When any of the touch buttons is pressed, those icons
will appear and are ready to operate (default).
2. B) Mode. The transmitter always displays all available
icons showing current status of timer,
blower, light and AUX as shown in the fi gure on the
right.
Press TIMER and THERMO buttons at the same time for
3 seconds to toggle between A) and B).
1. When the current setting is A), touch any place in the
touch area to bring up the icons then press TIMER but-
ton and THERMO button at the same time for 3 sec-
onds. The backlight will fl ash once to indicate that the
setting has changed to B).
AVFL Vent Free Fireplace
in
Figure 25
®
thermostat,
25