7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner.
If needed, keep ignitor button pressed in
until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob
counterclockwise
position.
10. Wait one minute and switch selector
switch to the ON position to light burners
(see Figure 56). When using in the ON
position (without remote) burners will
light on high. There is no adjustment to
the flames without using remote.
11. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
26
OPERATION
Continued
to the ON
to the
www.SuperiorFireplaces.US.com
ON REMOTE OFF
Figure 56 - Remote Selector Switch in
ON Position
Pilot
Burner
Figure 57 - Pilot (Natural)
Pilot
Burner
Figure 58 - Pilot (Propane/LP)
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
OFF position.
2. Set selector switch in the OFF position.
3. Close equipment shutoff valve (see Figure
15, page 16).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting
Instructions, page 28.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11 under Lighting Instructions,
page 29.