Unit Fails To Operate In The Cooling, Heating, Or Continuous Fan Mode; Unit Fails To Fire In The Heating Mode, Combustion Air Blower Does Not Energize - Lennox G61MPV Service Manual

G61mpv series
Hide thumbs Also See for G61MPV:
Table of Contents

Advertisement

PROBLEM 1: UNIT FAILS TO OPERATE IN THE COOLING, HEATING, OR CONTINUOUS FAN MODE
Condition
1.5
− Diagnostic lights flash the improper
main ground.
g
LED#1−Alternating Fast Flash
LED#2 Alternating Fast Flash
LED#2−Alternating Fast Flash
PROBLEM 2: UNIT FAILS TO FIRE IN THE HEATING MODE, COMBUSTION AIR BLOWER DOES NOT
Condition
2.1
− Unit operates with a cooling or contin-
uous fan demand.
− Combustion air inducer will not start
with a Heating demand.
− Diagnostic lights flash the limit failure
g
g
mode.
d
LED#1−Slow Flash,
LED#2−On
2.2
− Unit operates with a cooling and con-
tinuous fan demand.
− Combustion air inducer will not start
with a Heating demand.
− Diagnostic lights flash the pressure
switch failure code.
switch failure code
LED#1−Off,
LED#2−Slow Flash
Possible Cause
1.5.1
Improper ground to the unit.
1.5.2
6−Pin connector is improperly
attached to the circuit board.
1.5.3
Line voltage is below 75V.
1.5.4
Open ignitor circuit.
1.5.5
Broken or failed ignitor.
ENERGIZE
Possible Cause
2.1.1
Primary, secondary or backup secon-
dary (if equipped ) limit open.
2.1.2
Miswiring of furnace or improper
connections at limit switch(es).
2.2.1
Miswiring of furnace or improper
connections to combustion air
inducer.
2.2.2
Prove switch stuck closed.
Page 92
Corrective Action / Comments
ACTION 1 − Check that the unit is properly
ground.
ACTION 2 − Install a proper main ground to the
unit
ACTION 1 − Check 6−pin connector for proper
installation. Correctly insert connector into con-
trol.
ACTION 1 − Check that the line voltage is above
75V. Determine cause of voltage drop and supply
correct voltage to the control.
ACTION 1 − Check for correct wiring and loose
connections in the ignitor circuit. Check mult−plug
connections for correct installation.
ACTION 1 − Unplug ignitor and read resistance
across ignitor. If resistance does not read be-
tween 10.9 and 19.7 ohms, replace the ignitor.
Corrective Action / Comments
ACTION 1 − Check continuity across switch(es).
Switches reset automatically upon cool down.
ACTION 2 − Check for restrictions on blower inlet
air (including filter) and outlet air. Determine
cause for limit activation before placing unit back
in operation.
ACTION 1 − Check for correct wiring and loose
connections. Correct wiring and/or replace any
loose connections.
ACTION 1 − Check for correct wiring and loose
connections. Correct wiring and/or replace any
loose connections.
ACTION 1 − Check that the prove switch is open
without the combustion air inducer operating. Re-
place if defective.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents