VIII− Field Wiring Applications and Jumper Settings
A−SureLight Board 49M59
Thermostat
Thermostat
1 Heat / 1 Cool
NOTE − Use dip switch
3 to set second−stage
heat ON delay.
ON−10 minutes.
OFF−15 minutes.
51M26 SignatureStat
NOTE − Use dip
switch 3 to set sec-
ond−stage heat ON
delay.
ON−10 minutes.
OFF−15 minutes.
1 Heat / 1 Cool
with CCB1
NOTE − Use dip switch
3 to set second−stage
heat ON delay.
ON−10 minutes.
OFF−15 minutes.
1 Heat / 2 Cool
NOTE − Use dip switch
3 to set second−stage
heat ON delay.
ON−10 minutes.
OFF−15 minutes.

Field Wiring Applications

Jumper Settings (See figure 4)
E20
W915
SINGLE
Intact
SINGLE
Intact
SINGLE
Intact
SINGLE
Cut
TABLE 44
W914
W951
Intact
Intact
Cut
Intact
Cut
Intact
Intact
Intact
Page 86
Wiring Connections
Wiring Connections
S1
CONTROL
T'STAT
TERM. STRIP
CONTROL
OUTDOOR
51M26
TERM. STRIP
T'STAT
S1
CONTROL
CCB1
T'STAT
TERM. STRIP
S1
CONTROL
OUTDOOR
T'STAT
TERM. STRIP
OUTDOOR
UNIT
HSXB15
(LSOM)
UNIT
HSXB15
(LSOM)
OUTDOOR
UNIT
HSXB15
(LSOM)
UNIT
HSXA19
(LSOM)