CONTINUOUS LOW SPEED FAN SEQUENCE OF OPERATION

MANUAL FAN SELECTION MADE AT THERMOSTAT.
AFTER 2 SECOND DELAY, INDOOR BLOWER IS
ENERGIZED ON CONTINUOUS FAN SPEED.
YES
YES
THERMOSTAT CALLS FOR FIRST STAGE COOL.
THERMOSTAT CALLS FOR FIRST−STAGE HEAT.
YES
YES
INDOOR BLOWER RAMPS TO FIRST STAGE
AFTER 45−SECOND DELAY, INDOOR BLOWER
COOLING SPEED AFTER A 2−SECOND DELAY.
SWITCHES TO LOW HEAT SPEED.
FIRST−STAGE COOL DEMAND SATISFIED?
FIRST−STAGE HEAT DEMAND SATISFIED.
YES
YES
NO
NO
SECOND STAGE COOL DEMAND
THERMOSTAT CALLS FOR SECOND−STAGE HEAT.
YES
INDOOR BLOWER RAMPS TO SECOND
INDOOR BLOWER SWITCHES TO HIGH HEAT SPEED
STAGE COOL SPEED
AFTER 30−SECOND RECOGNITION PERIOD.
YES
SECOND STAGE COOL DEMAND SATISFIED?
SECOND−STAGE HEAT DEMAND SATISFIED.
YES
YES
INDOOR BLOWER RAMPS DOWN TO FIRST STAGE
INDOOR BLOWER RAMPS DOWN TO LOW
COOL SPEED.
HEAT SPEED.