3-52
ENGINE CONTROL SYSTEM
INSPECTION FOR RESISTANCE
" 09930-99320: Digital tester
& Tester range: Ω (Resistance, See chart for range.)
NOTE:
Make sure ignition switch is always OFF when measuring resis-
tance.
1. Turn ignition switch OFF.
2. Disconnect battery cables from battery.
3. Disconnect wire harness connector from ECM.
4. Connect the tester probes to terminal (wire harness side)
and measure resistance according to the "RESISTANCE
TABLE".
35 34 33 32 31 30 29 28 27
43 42 41 40 39 38 37 36
51 50 49 48 47 46 45 44
60 59 58 57 56 55 54 53
NOTE 1:
Pull out ECM main relay, and connect tester probe to terminal
( "A", Gray wire) of ECM main relay.
NOTE 2:
Disconnect remote control wire harness and connect tester
probe to terminal ( "B", White wire).
52
Wire harness
7 6 5 4 3 2 1
13 12 11 10 9 8
19 18 17 16 15 14
26 25 24 23 22 21 20
• Gray wire
ECM main relay
16 Pin connector
B White
lead wire