8

Electrical connections

8
Electrical connections
Devices such as pumps, outdoor sensor and 3-way
valve are all connected to the external connection board.
The electrical connections to the appliance must be
made in accordance with all applicable local codes and
the latest revision of the National Electrical Code,
ANSI/NFPA-70
Installations should also conform with CSA C22.
1 Canadian Electrical Code Part 1 if installed in Canada.
8.1
External connection board
connections
Make all electrical connections inside the external
connection box.
Remove the cover of the external connection box
(fig. 22).
Connecting incoming power
The appliance must be electrically grounded
in accordance with local codes, or in absence
of local codes, with the National Electrical
Code, ANSI/INFPA 70 and/or the
CSA C22.1, Electrical Code.
Install a 120V cable to the appliance (see fig. 23,
pos. 1).
Lead the cable through the cable guide (see fig. 23,
pos. 2).
Terminals 1 – 6 (fig. 24) are low-voltage connections
and terminals 7 – 10 (fig. 24) are 120 Volt connections.
CAUTION
Risk of electric shock.
Once the main power supply is on then there
is 120V on terminals 7 – 10 (can only be
used with the correct configuration of the
control unit and specific system hydraulics),
if the main switch of the BC10 basic
controller is switched on.
RC terminal
Connector for installation of an RC controller for indoor
reset operation or a module.
FA terminal
This is the terminal where you connect the outdoor
temperature sensor. Only necessary for outdoor
weather responsive operation.
WA terminal
For connection of a potential free thermostat or relay
panel end switch.
FW
Connection for an external DHW tank sensor
We reserve the right to make any changes due to technical modifications!
24
Installation and Servicing Instructions Logamax plus GB142-24/30/45/60 • Version 12/2004
Fig. 22 Removing the cover from the external connection box
Fig. 23 external connection board
FA
FW
RC
WA
EV
DWV
1 2 3 4
5
6
Fig. 24 Connections to external connection board
Abbr. Color
Component
RC
orange
RC Room thermostat connection for a
module
FA
blue
Outdoor-temperature sensor
WA
green
Potential-free On/Off thermostat
FW
gray
DHW temperature sensor
EV
red
External switching contact, potential-free
for floor heating safety etc.
DWV green
Connection for external 3-way valve
PK
green
Primary loop pump 120V 60Hz
PS
gray
DHW tank pump 120V 60Hz
PZ
lilac
DHW recirculating pump 120V 60Hz
Netz
white
main connection 120V 60Hz
Buderus Hydronic Systems • http://www.buderus.net
1
2
PZ Netz
PK PS
7
8
9
10