Requirements For Ul/Ulc Listed Rigid Pp(S) Vent Pipe Material - Viessmann Vitodens 100-W WB1B Series Installation Instructions Manual

Rigid pipe venting systems
Table of Contents

Advertisement

Rigid Venting Systems Installation Instructions

Requirements for UL/ULC Listed Rigid PP(s) Vent Pipe Material

IMPORTANT
When replacing parts, use manufacturer's original
replacement parts.
The venting system must be installed by a licensed
professional heating contractor familiar with the operation
and maintenance of heating appliances and venting.
Before installing this product, ensure that the complete
installation literature has been read. Failure to follow proper
installation procedures as stated in these instructions,
including vent pitch and proper appliance connections,
may violate local, provincial/state, or national codes and
cause unsafe conditions which may lead to severe property
damage or personal injury.
Prior to installation, check that the correct single-pipe vent
parts were ordered and supplied.
The venting system must be installed in accordance with
local building code requirements as well as national codes.
For installations in Canada use CAN/CSA-B149.1 Natural
Gas Installation Code or CAN/CSA-B149.2 Propane
Installation Code as applicable; in the U.S. use the
National Fuel Gas Code ANSI Z223.1 or NFPA Standard 54.
To ensure safe operation of the appliance, Viessmann
recommends that the system be inspected once a year by
a qualified service technician.
Every venting system must be planned and installed for
optimum performance and safety. These Installation
Instructions are designed to help you determine venting
requirements and limitations with respect to installation.
Please read and follow these instructions carefully.
It is the responsibility of the installer to contact local
building and fire officials concerning any installation
restrictions and/or inspection requirements that may apply.
Permits may be required before commencement of the
installation.
Vent System Manufacturers
The following Coaxial and PP(s) vent system manufacturers
may be contacted for assistance in designing the appropriate
venting system for Vitodens 100 and Vitodens 200 boilers.
Both manufacturers deliver PP(s) rigid and flexible vents in
three sizes.
M&G / Duravent
Tel. 800-835-4429
Fax. 518-649-9700
Fax: 518-463-5271
sales@duravent.com
www.duravent.com
2 in. (60 mm)
3 in. (80 mm)
4 in. (100 mm)
Centrotherm InnoFlue
Eco Systems. LLC
418 South Pearl St.
Albany, New York 12202
Tel. (518) 434-3400
Fax. (518) 618-3166
info@centrotherm.us.com
www.centrotherm.us.com
2 in. (60 mm)
3 in. (80 mm)
4.3 in. (110 mm)
Direct Venting (Two-pipe System)
Both manufacturers deliver PP(s) concentric vents in three
sizes.
M&G / Duravent
2 - 4 in. (60 - 100 mm)
3 - 5 in. (80 - 125 mm)
4 - 6 in. (100 - 150 mm)
For Vitodens WB2B 80, 105 (with boiler flue adaptor 110
- 150) the vent manufacturers developed special transition
adaptors.
The air intake termination for side wall air intake
installations should be located on a wall that is least
affected by prevailing winds. High winds may affect
boiler operation.
Because of its sealed combustion chamber, the Vitodens
gas-fired condensing boiler is suitable for operation with
balanced flue.
The Vitodens boiler, flue gas adaptor and parallel adaptor
(if used) are approved together under CSA 4.9. ANSI
Z21.13 - 2010 Standard.
The venting system components are tested and listed to
ULC S636 or UL 1738 by Intertek and are marked and
labelled on each component.
IMPORTANT
DO NOT mix pipe, fittings, or joining methods from
different vent system manufacturers.
DO NOT use adhesives of any kind with this venting
system.
The vent length requirements stated in this manual
(starting on page 21 for side wall vent installations and
page 28 for vertical vent installations) must be observed.
Flue gases are discharged via rigid PP(s) vent components
to the outdoors. This vent system is constructed from
flame-retardant plastic [polypropylene rated for a maximum
temperature of 230º F (110º C)].
Centrotherm InnoFlue
2 in. (60 mm)
3 in. (80 mm)
4.3 - 6.3 in. (110 - 160 mm)
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-w wb2b series

Table of Contents