Exhaust Vent Termination Options (Vertical Installation); Other Exhaust Vent Termination Options (Horizontal Installation); Maximum Equivalent Length - Viessmann Vitodens 100-W WB1B Series Installation Instructions Manual

Rigid pipe venting systems
Table of Contents

Advertisement

Direct Venting (Two-pipe System)
Vent Requirements - Stainless Steel
Additional requirements for stainless steel vent pipe material
(continued)
Table 19. Exhaust vent termination options (vertical installation)
Supplier
Boiler Model
Flexmaster
WB1B 26. 35, WB2B 19, 26, 35
g
WB2B 45, 60
g
WB2B 80, 105
g
Heat-Fab
WB1B 26. 35, WB2B 19, 26, 35
g
WB2B 45, 60
g
WB2B 80, 105
g
ProTech
WB1B 26. 35, WB2B 19, 26, 35
g
WB2B 45, 60
g
WB2B 80, 105
g
Security
WB1B 26. 35, WB2B 19, 26, 35
g
Chimneys
WB2B 45, 60
g
WB2B 80, 105
g
Table 20. Other exhaust vent termination options (horizontal installation)
Supplier
Boiler Model
Flexmaster
WB1B 26. 35
g
WB2B 19, 26, 35
WB2B 45, 60
g
WB2B 80, 105
g
Heat-Fab
WB1B 26. 35
g
WB2B 19, 26, 35
WB2B 45, 60
g
WB2B 80, 105
g
ProTech
WB1B 26. 35
g
WB2B 19, 26, 35
WB2B 45, 60
g
WB2B 80, 105
g
These tables reflect the parts required if using special venting system for both exhaust vent and air intake pipe system.
If using ABS/PVC/CPVC material for combustion air intake pipe, (refer to table 22 for proper starter adaptor for the system).
Table 21. Maximum equivalent length Vitodens 100 / 200-W WB2B Series (horizontally or vertically vented)
Boiler model
WB1B 26, 35
g
WB2B 19, 26, 35
g
WB2B 45, 60
g
WB2B 80, 105
g
Note: For combination of different vent/air intake pipe diameters, such as Ø 3 in. stainless steel vent with Ø 2 in. (CVPC, PVC,
ABS) air intake pipe, the total equivalent length must be used for the smaller pipe diameter. See tables 24, 25 and 26.
42
Termination Elbow with Screen
90° or 45° (see fig. 37)
ft. (m)
ft. (m)
ft. (m)
ft. (m)
Rigid Venting Systems Installation Instructions
(continued)
Stainless Steel Slip
Joint Starter Adaptor
3 in.
2SVSVB03
3 in.
2SVSVB03
4 in.
2SVSVB04
3 in.
9301VSMN
3 in.
9301VSMN
4 in.
9401VSMN
3 in.
300568
3 in.
300568
4 in.
300569
3 in.
CTX-V3
3 in.
CTX-V3
4 in.
CTX-V4
Termination Tee with
Screen (see fig. 38)
Contact
supplier
Contact
supplier
Contact
supplier
Stainless Steel Vent Diameter
3 in.
164 (50)
148 (45)
98 (30)
-
Vertical Termination
Coupling with Screen (see fig. 36)
3 in.
2SVST03
3 in.
2SVST03
4 in.
2SVST04
3 in.
9392
3 in.
9392
4 in.
9492
3 in.
300186
3 in.
300186
4 in.
300187
Contact
supplier
Termination Hood with
Screen (see fig. 39)
Contact
Contact
supplier
Contact
Contact
supplier
Contact
Contact
supplier
4 in.
200 (61)
180 (55)
148 (45)
131 (40)
supplier
supplier
supplier