CDA HVC70 Manual For Installation, Use And Maintenance page 19

Hvc70 four zone ceramic hob
Table of Contents

Advertisement

CONNECTING THE FEEDER CABLE
To connect the feeder cable to the hob it is necessary to carry out the following opera-
tions:
Unscrew the screw A of the terminal board at the bottom of the hob (fig. 4.1).
Unlock the 2 clips B and open the cover C.
• Unscrew the screw D and open completely the cable clamp E
Position the U bolts F onto terminal board G (fig. 4.3) according to the diagram in fig. 4.2.
Connect the phase and earth wires to terminal board G according to the diagram in
figs. 4.2 and 4.3.
Strain the feeder cable and block it with cable clamp E (by screwing screw D).
Close the cover C of the terminal board G and block it with the screw A.
FEEDER CABLE SECTION
"Type H05VV-F or H05V2V2-F or H05RR-F"
~
220-240 V
3 x 2,5 mm
~
220-240 V
3 x 4 mm
(**) Connection with wall box connection.
– Diversity factor applied
– A diversity factor may be applied to the total loading of the appliance only by a suit-
ably qualified person
2
(**) for 60 cm and 80 cm models
2
(**)
for 90 cm models
C
G
L
F
(fig.
4.3).
E
N
D
E
Fig. 4.3
19

Advertisement

Table of Contents
loading

Table of Contents