SMA SUNNY BOY 3000-US Installation Manual page 69

Pv inverter
Hide thumbs Also See for SUNNY BOY 3000-US:
Table of Contents

Advertisement

SMA America, LLC
Name
Description
Memory Function
Operating Mode Operating modes of an
inverter
T-Max-Fan
Temperature at which the
fan reaches the maximum
fan speed.
T-Start
Gird monitoring time:
Time during which the
inverter monitors the
power distribution grid
before connecting.
This value defaults to
5 minutes after a grid fault.
Installation Manual
Value/range
Explanation
no function
Default param.
Sets all
parameters to
the standard
value.
Reset Op.Data
Sets all
parameters that
are visible on
the user level to
the standard
values.
Reset errors
Resets all
permanent
errors that lead
to device
disconnection.
MPP-Operation
Sets the inverter
to the operating
mode "MPP"
Turbine
Sets the inverter
to the operating
mode "Turbine"
V-const
Sets the inverter
to the operating
mode "V-Const"
Stop
Disconnection
from the power
distribution grid,
no operation
32°F to 212°F
(0°C to 100°C)
5 s to 1,600 s
10  Troubleshooting
Default
value
no function
MPP
194°F
(90°C)
10 s
SB30-40-US-IA-en-33