Electrical Connection; Safety During Electrical Connection - SMA SUNNY BOY 3000-US Installation Manual

Pv inverter
Hide thumbs Also See for SUNNY BOY 3000-US:
Table of Contents

Advertisement

SMA America, LLC
6

Electrical Connection

6.1 Safety During Electrical Connection

Danger to life due to high voltages in PV modules that are exposed to light
Death or serious injury due to electric shock as a result of touching a DC cable.
• During the installation of the inverter, cover the PV modules with opaque material.
Risk of damage to the inverter due to moisture penetration
Electronic components in the inverter can be destroyed or damaged as a result of moisture
penetration.
• For inserting the conduits into the DC Disconnect, use UL-certified rainproof sleeves or
waterproof sleeves that fulfill UL 514B only.
Risk of damage to or failure of the inverter due to the use of Wire Nuts
The use of Wire Nuts
lead to inverter damage or failure.
• Do not use any Wire Nuts
Installation Manual
®
may cause ground-faults or prohibited and high-ohm connections, which can
®
for electrical connections in the PV system.
6  Electrical Connection
®
SB30-40-US-IA-en-33
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents