DCR-DVD100/DVD100E

4. White Balance Adjustment (VC-307 board)

Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC2201
Note2: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
2
B
56
8D
3
B
57
4
B
57
5
B
56
6
B
56
7
B
57
8
B
57
9
B
57
10
0
01
MOVIE (
)
Arbitrary
Check on EVF screen
B
56, 57
The EVF screen should not be colored.
Procedure
01
Set the data.
Set the data, and press PAUSE
button.
73
Set the data, and press PAUSE
button.
Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
Change the data so that the EVF
screen is not colored.
Press PAUSE button.
Change the data so that the EVF
screen is not colored.
Press PAUSE button.
If the EVF screen is colored,
repeat steps 5 to 9.
00
Set the data.