DCR-DVD100/DVD100E
10. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Adjustment Page
Adjustment Address
Note1: This adjustment should be carried out upon completion of "Flange
back adjustment" and "Optical Axis Adjustment".
Note2: The data of page: 0, address: 10 must be "00".
Note3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) MODE ............................................................. MOVIE (
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
48
3
6
2C
4
6
96
5
6
97
6
6
01
7
6
02
Note4: The adjustment data will be automatically input to page: F, address:
17.
Processing after Completing Adjustments
Order Page Address Data
1
6
2C
2
6
48
3
6
96
4
6
97
5
6
01
6
0
01
Clear chart
(Color reproduction adjustment frame)
F
17
Procedure
01
Set the data.
02
Set the data.
01
Set the data.
Set the following data.
28 (NTSC), 1C (PAL)
Set the following data.
80 (NTSC), 00 (PAL)
6F
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Procedure
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
11. LV Standard Data Input
And adjust the normal coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: This adjustment should be carried out upon completion of "Flange
back adjustment", "Optical Axis Adjustment", "Color reproduction
adjustment" and "MAX GAIN Adjustment".
Note2: The data of page: 0, address: 10 must be "00".
Note3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
)
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1) MODE ............................................................. MOVIE (
2) NIGHT SHOT .................................................................. OFF
3) FOCUS .................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
48
3
6
01
4
6
02
5
0
03
6
1
Note5: The adjustment data will be automatically input to page: F, address:
18, 19.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
48
3
0
03
4
0
01
5
6-22
Clear chart
(Color reproduction adjustment frame)
Display data of page 1 (Note4)
Adjustment remote commander
F
18, 19
0FB0 to 1050
Display data
Procedure
01
Set the data.
02
Set the data.
0D
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note5)
1E
Set the data.
Check that the display data
(Note5) satisfies the specified
value.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
00
Set the data.
Perform "Auto White Balance
Standard Data Input".
)