3-1. Specifications

Rated Welding
Maximum
Output
Amperage
90 A @ 19 Volts DC,
20% Duty Cycle
63 A @ 21 Volts DC,
20% Duty Cycle*
Wire Type
And Dia
* CSA Rating

3-2. Duty Cycle And Overheating

200
135
100
80
60
40
20
10
2
1
Overheating
SECTION 3 − SPECIFICATIONS
Maximum Open-
Circuit Voltage
DC
125
29
Flux Cored
.030 − .035 in
(0.8 − 0.9 mm)
10
4
6
8
Duty Cycle %
20% duty cycle at 90 amps
2 Minutes Welding
Minutes
Amperes Input at
Rated Load Output
KVA
115 V, 60 Hz, Single-
Phase
20
2.90
15*
2.20*
Wire Feed Speed Range
183 − 295 IPM (4.6 − 7.5 m/min) At No Load
112 − 236 IPM (2.8 − 6.0 m/min) Feeding Wire
40
60
20
8 Minutes Resting
0
15
Reduce Duty Cycle
Weight
Overall
KW
W/ Gun
Dimensions
Length: 16-7/8 in
(429 mm)
2.50
50 lb
Width: 9-7/8 in
(22.7 kg)
(251 mm)
1.77*
Height: 12-1/8 in
(308 mm)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit or gun and void
warranty.
100
A or V
OR
duty1 4/95 − 210 517-A
OM-923 Page 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

H-9b gun