Section 4 − Specifications; Serial Number And Rating Label Location; Software Licensing Agreement; Information About Default Weld Parameters And Settings - Hobart IronMan 240 Owner's Manual

Table of Contents

Advertisement

4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on back. Use rating label to determine input power requirements and/or rated output.
For future reference, write serial number in space provided on back cover of this manual.

4-2. Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.hobartwelders.com/eula

4-3. Information About Default Weld Parameters And Settings

NOTICE − Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical welding
parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are for reference
purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriateness of all parameters
and settings should be evaluated and modified by the end user as necessary based upon application-specific requirements. The end user is solely
responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld parameters and settings, and ultimate
quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warranties including any implied warranty of fitness
for a particular purpose.

4-4. Welding Power Source Specifications

Rated Welding
Amperage Range
Output
250 A, 26.5 volts DC,
30−280 A
40% Duty Cycle
200 A, 24.0 volts DC,
30−280 A
60% Duty Cycle
Wire Type and Diameter
Solid Steel
Stainless Steel
.023 − .045 in.
.023 − .045 in.
(0.6 − 1.2 mm)
(0.6 − 1.2 mm)
*SpoolRunner 200 required for welding aluminum

4-5. Environmental Specifications

A. IP Rating
This equipment is designed for indoor use and is not intended to be used or stored outside.
B. Temperature Specifications
Operating Temperature Range*
-4 to 104°F (−20 to 40°C)
*Output is derated at temperatures above 104°F (40°C).
.
A complete Parts List is available at www.HobartWelders.com
SECTION 4 − SPECIFICATIONS
.
and are incorporated by reference herein.
Maximum Open-
Circuit Voltage DC
40
40
Flux Cored
Aluminum*
.030 − .045 in.
.030 − .047 in.
(0.8 − 1.2 mm)
(0.8 − 1.2 mm)
Amperes Input At Rated Load Output, 60 Hz, Single Phase
208 VAC
240 VAC
62.6
55.7
57.0
50.8
Wire Feed Speed
50−700 IPM
(1.3−17.8 m/min)
IP Rating
IP21
Storage/Transportation Temperature Range
−22 to 122°F (−30 to 50°C)
KVA
KW
12.6
11.4
Dimensions
Net Weight
Without Gun
H: 30 in. (762 mm)
205 lb
W: 19 in. (483 mm)
(93 kg)
D: 40 in. (1016 mm)
Temp_2016- 07
OM-284833 Page 11
9.4
7.1
IP21 2014−06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents