(2) Detaching and refitting the grid wire cleaning pad and main charger wire cleaning pad

Follow the procedure below to replace the grid wire cleaning pad and main charger wire cleaning pad.
Procedure
1. Remove the main charger grid (see page 1-6-
39).
2. Open the hinge of the grid wire cleaning pad
in the direction of the arrow 1 to remove
from pin, then remove the grid wire cleaning
pad.
3. Remove the two claws each (sections
indicated by round marks in the figure), then
remove the main charger wire cleaning pads.
4. Refit all the removed parts.
Grid wire cleaning pad
Pin
Hinge
Charger wire cleaning pads