GVF103-KT - PATENTED CATALYTIC

DOOR INSTALLATION

This unique patented catalytic system was designed to
provide unparalleled safety and peace of mind. The top of
the door contains four catalytic tiles which are designed to
filter out harmful gases and limit the carbon monoxide
output. It is likely that with the fireplace in operation, the
catalytic tiles will actually scrub the carbon monoxide nor-
mally found in the room and reduce it to a lower level. The
tiles must not be altered or removed. They are not field
serviceable and must be tested annually.
The heater with an optional catalytic door in place must not
be operated when using any products such as paint, paint
thinner, adhesives, etc. These products will permanently
affect the catalytic tiles' ability to scrub the air.
FIGURES 15
1
1. The mesh must be removed if the catalytic door is used.
Remove the centre bracket and bend the curtain rod slightly
to disengage the rod from either side.
LATCH SCREW
LOCATION
CURTAIN SUPPORT PLATE
2
2. Remove the curtain support plate. Remove the two latch
securing screws, already installed, position latch as shown
4
in
and re-secure with the screws. A ¼" socket ratchet
is recommended for this.
Repeat at the bottom. For location, see
OPTIONS
CURTAIN ROD BRACKET
5
.
3
3. Screw the door hinge onto the heater by first starting
each of the five machine screws and then tightening all
screws.
TOP DOOR LATCH
4
4. & 5. Secure the door using the two latches.
Replace the hood by hooking it over the top lip of the door
assembly.
The heater must not be used when the hood is removed.
BOTTOM DOOR LATCH
5
Care must be taken when closing and opening the cata-
lytic door to avoid damaging the catalytic tiles.
9
DOOR HINGE
WS-415-131 / A / 09.11.00