5. Operation check of MAIN (1) P.C.B.
o
a. Remove 2 screws (
). (Fig. 12)
* Arrow marks (
) are printed to identify the screws to be
removed.
!0
b. Remove 3 screws (
) and 2 screws (
c. Loosen the harness fixture fixing the cable.
d. Raise the Amp Unit from the front toward the back.
e. Put an insulating sheet under the Amp Unit before per-
forming any checks for proper operation.

When checking the P.C.B.:

• Reconnect all cables (connectors) that have been disconnected.
• When connecting the flat cable, use care for the polarity.
• The P.C.B. removed from the rear panel does not work because
its grounding is loose. Be sure to connect the ground of each
P.C.B. to the chassis or GND with a jumper wire or the like.