Citizen CL-S700 User Manual page 47

Thermal transfer barcode & label printer
Hide thumbs Also See for CL-S700:
Table of Contents

Advertisement

Installing the Media (p.24)
Quick Sensor Selection
Method
(Transparent ↔ Reflective)
(p.46)
Adjusting the Transparent sensor
1. The transparent sensor is selected.
2. Install only the liner media (label backing paper) with the label
media removed so that it will pass between the platen roller and
the media sensor. (Be careful that media with black marks does
not pass the media sensor.) Then close the sensor arm and the
printhead.
Upper sensor
Bottom sensor
3. If the Pause Key is pressed then released while the MENU key is
continually pressed, the sensor is automatically adjusted.
4. When automatic adjustment stops normally, "Succeeded" is
displayed by the LCD. If it stops abnormally (adjustment is
impossible), ERROR LED flashes and "Failed" is displayed on
the LCD.
5. If the STOP key is pressed, the Printer completes sensor
adjustment and the printer restarts.
47
Printer Adjustments
Sensor Adjustments and Calibration
Label
Media gap
Liner media
Sensor Cal Mode
Executing
Sensor Cal Mode
Succeeded
PAUSE
MENU
Hold
Press/Release