Printer Adjustments
Printer Adjustments
Installing the Media (p.24)

Sensor Adjustments and Calibration

The sensing level of both the transparent (see thru) and reflective sensors is
adjusted separately and independently. Firstly, the sensor type must be
selected using the Sensor Method Selection shown below. Then the
adjustment and calibration of the sensor can be made.
The front sensor or adjustable sensor is selected using the Adjustable sensor
on the sub menu that is in Page Setup on the main menu. (See "Chapter 2.
Printer Operation"). The adjustable rear sensor is set by Factory Default.
Entering Sensor Adjustment Mode
1. Turn on the power while pushing the PAUSE key, FEED key, and
STOP key simultaneously.
PAUSE
FEED
STOP
2. After "Sensor Cal Mode" lights up, release the keys to change
the printer to sensor adjustment setting mode.
Quick Sensor Selection Method
(Transparent ↔ Reflective)
To switch from transparent to reflective sensor, hold down the MENU key
and then press the STOP key. Each time you press the STOP key, you switch
to back and forth between the two sensor types.
If the transparent sensor is selected, "See Through" is displayed and the
buzzer sounds once. If the reflective sensor is selected, "Reflect" is displayed
and the buzzer sounds twice.
Sensor Cal Mode
Reflect
POWER
46
Power Switch
Sensor Cal Mode
See Through
POWER
ERROR
MENU
Hold
ERROR
STOP
Press/Release