D. Vent Diagrams
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
1. Top Vent - Horizontal Termination
One Elbow
Figure 5.3
Two Elbows
Figure 5.4
WARNING
Heat & Glo • Bravo • 704-902 Rev. D • 5/08
V
Minimum
H
1
3 ft.
0.9 m
2 ft.
4 ft.
1.2 m
4 ft.
5 ft.
1.5 m
6 ft.
12 ft.
3.7m
20 ft.
V
+ H
= 40 ft. (12.2 m) Maximum
1
1
H
= 20 ft. (6.1 m) Maximum
1
Note: When installing the TAOS surround
and venting with one elbow, a straight sec-
tion of venting (30 in. minimum) MUST be
attached directly to starting collars on unit.
Note: The fi rst elbow used MUST always
be DVP90ST.
V
Minimum
H
+ H
1
1
3 ft.
0.9 m
2 ft.
4 ft.
1.2 m
4 ft.
5 ft.
1.5 m
6 ft.
12 ft.
3.7 m
20 ft.
V
+ H
+ H
= 40 ft. (12.2 m) Maximum
1
1
2
H
+ H
= 20 ft. (6.1 m) Maximum
1
2
V
Note:
MUST be a minimum
1
of 3 feet unless using the TAOS
surround. For TAOS surround, V
minimum MUST be 30 in.
Note: The first elbow used
MUST always be DVP90ST.
Maximum
1
0.6 m
1.2 m
1.8 m
6.1 m
Maximum
2
0.6 m
1.2 m
1.8 m
6.1 m
1
13